SKU 2178169  UPC 0799705792913

High Density GE Analog Output 8PT IC693A Current / Voltage allowing eight single IC693ALG

Technical Specifications
  • Number of Output Channels 1 to 8 selectable
  • Output Current Range 4 to 20 mA and 0 to 20 mA
  • User Supply Voltage (nominal) +24 VDC, from user supplied voltage source
  • Isolation 1500 volts between field and logic side
  • 110 mA from +5V PLC backplane supply
  • Update Rate 8 msec (approximate, all eight channels)
Troubleshooting and Product Information for IC693ALG392

Download product information, troubleshooting guides and operation manuals to get your PLC operational.

Technical Information

Analog Output 8PT IC693A IC693AL IC693ALG

New IC693ALG392
Price: $1,695
8 In Stock 1 Year Warranty
Wt: 2 Lbs

*Need a Specific Revision?

New Surplus IC693ALG392
Price: $995
9 In Stock 3 Year Warranty
Wt: 2 Lbs

*What is New Surplus?

Reman IC693ALG392
Price: $490
9 In Stock
2 Year Warranty
Wt: 2 Lbs

*What is Remanufactured?

Save
 71%

1C693ALG392 , GEFIC693ALG392 , CIMIC693ALG392

Revisions Information


Series 90-30 Analog Output Module, Current/Voltage, 8 Channel, IC693ALG392

The 8–Channel Analog Current/Voltage Output module; IC69*ALG392, provides up to eight single-ended output channels with current loop outputs and/or voltage outputs. Each output channel can be set up using the configuration software for any of these ranges:

        0 to +10 volts (unipolar)

        -10 to +10 volts (bipolar)

        0 to 20 milliamps

        4 to 20 milliamps

Each channel is capable of converting 15 to 16 bits (depending on the range selected) of binary data to an analog output. All eight channels are updated every 8 milliseconds.

In current modes, the module reports an Open Wire fault to the CPU for each channel. The module can go to a known last state when system power is interrupted. As long as external power is applied to the module, each output will maintain its last value or reset to zero, as configured.

This module can be installed in any I/O slot of an RX3i system.

 

Isolated +24 VDC Power

The module must receive its 24 VDC power from an external source, which must be connected directly to the module’s terminal block.

 

 

Compatibility

Series 90-30 PLC CPU: for CPU firmware versions 3.3 to 4.6, the module must be configured for 16 %I inputs or a Loss of Module Fault will occur. CPU firmware must be version 5.0 or later to configure the module for 8% I inputs.

Hand-Held Programmer: Only Series 90-30 modules IC693ALG392 version C or earlier support the Series 90-30 Hand- held Programmer. Series 90-30 modules IC693ALG392 version BD or later and RX3i modules IC694ALG392 (all versions) cannot be used with a Hand-held Programmer.

 

Release History

 

Version

Date

Description

IC693ALG392-BD IC694ALG392-BB

 

January 2009

Updated processor and D/A converter.

IC693ALG392-BB or later is not compatible with a Series 90-30 Hand-held Programmer.

IC693ALG392-C

February 2005

ATEX approval for Group 2, category 3 applications.

IC694ALG392-AA

July 2004

Initial product release

IC693ALG392-B

October 1995

CE certification

IC693ALG392-A

n/a

Initial product release

New Features

When used in a PACSystems RX3i, modules IC693ALG392 version BD or later and IC694ALG392 version BB or later can be field-upgraded using Winloader.

Proficy Machine Edition displays the module firmware revision level for modules IC693ALG392 version BD or later and IC694ALG392 version BB or later in PACSystems RX3i targets.

 

Current and Voltage Ranges and Resolution

In the 4 to 20mA range, the module scans output data from the PLC so that 4mA corresponds to a count of 0, and 20mA corresponds to a count of 32000. In the 0 to 20mA range, user data is scaled so that 0 mA corresponds to a count of 0 and 20mA corresponds to 32000. In 0 to 20mA mode, a value up to 32767 provides a maximum output of approximately 20.5mA.  In current mode, the module also reports an open loop fault to the PLC.

For voltage operation in the default unipolar mode (0 to +10 volts), data is scaled so that 0 volts corresponds to a count of 0 and +10 volts corresponds to a count of 32000. In this mode, a value up to 32767 creates an overrange output of approximately 10.24 volts.

In the -10 to +10 volt range, data is scaled so that -10 volts corresponds to a count of -32000 and +10 volts corresponds to a count of +32000. In this range, output values from -32767 to +32767 result in an overrange of approximately -10.24 volts to +10.24 volts.

Scaling for both current and voltage ranges is shown below.

 

LEDs

The Module OK LED indicates module status. The User Supply LED indicates whether the external +24 VDC power supply is present and is above the minimum level. Both LEDs are powered from the +5 VDC backplane power bus.

 

LED

Indicates

OK

ON:        Module OK and configured

Flashing: Module OK but not configured

OFF:       Module is defective or no +5V backplane power present

USER OK

ON:        External power supply present

OFF:       No user power

 

Installation in Hazardous Locations

·         EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY

·         WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;

·         WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND

·         WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS