HE693ADC420

Rated 4.7/5 Based on 10 ratings.

Rate your purchase of the HE693ADC420

Horner Electric | Horner Electric | HE693ADC420 | Image

Horner Electric | Horner Electric | HE693ADC420 | Image Horner Electric | Horner Electric | HE693ADC420 | Image

SKU 2174459  UPC 0563013854546

MSRP $3995

Reman

$1450

(Save 63%)

2 In Stock

2 Year warranty

*What is
Remanufactured?

Repair

$995

(Save 75%)

Fast Turnaround

1 Year warranty

1-800-360-6802

Order Today - Ships Today!


*US continental orders placed before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the HE693ADC420 ABCDEFGHIJKLMNOPQRSTUVWXYZ

The HE693ADC420 is an Isolated Analog Current Input Module from Horner Electric. This module is a 14-bit resolution unit with four analog input channels. It also has 1500 VAC isolation, which is much more than the 500 VAC of the smaller HE693ADC415 model. Both of these modules work the same way. They convert the current input signal to digital values. These are then placed into the %AI table of the PLC CPU. The isolation levels are channel-to-channel and channel-to-ground.

Each channel on the module can be configured to one of two input ranges. The user may set it to either 4- 20mA or +/-20mA. Each one of the four channels also has a programmable set-point. Its level is set through the PLC program. This is done by four %AQ output registers. Should the input value reach or exceed these set-points, a corresponding digital input %I will be energized. The first four digital input %I’s represent the four separate input channel set-point alarms of the module.

When intalling the Isolated Analog Current Input Module, it is important that wiring is routed into its own conduit. For the best noise immunity, the person installing the unit should use shielded, twister pair extension wiring. When using this type of wiring, it is critical that a good earth ground connection is made. This is only needed at one end. If the shields are grounded to the earth at the module end, terminals 1, 2, 11, and 12 will need to be used as the shield connection points.

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.