The IC695ALG306 is a 6-Channel Isolated Thermocouple Input module from the GE Fanuc RX3i Series. This module provides 6 isolated differential thermocouple input channels. The module must be located in an RX3i Universal Backplane. It requires an RX3i CPU with firmware version 5.5 or later.  See specifications for this unit on IC695ALG306's website page.

Technical Specifications


Module Type: Isolated Thermocouple Input
Number of Inputs:  6
Internal Power: 3.3V: 400mA;  5V: 150 mA
Number of Slots: 1 (single slot)
Types: J, K, T, E, R, S, B, N or C
Update Rate:    15 msec to 120 msec (configurable) 

 

 

GE Intelligent Platforms / GE Fanuc GE RX3i PacSystem

SKU 2171213  UPC 0583515868988

Part Number: IC695ALG306 / ic695alg306
Mfr/Brand Name: GE Automation
Mfr Number: IC695ALG306 / ic695alg306
Type: Isolated Thermocouple Input Module, 6 Channels

Troubleshooting and Product Information for IC695ALG306

Download product information, troubleshooting guides and operation manuals to get your PLC operational.

New IC695ALG306
Price: $1,723
2 In Stock
1 Year Warranty

*Need a Specific Revision?

Repair Your IC695ALG306
Price: $675
1 Year PDF Supply Warranty
Call For Assistance
1-800-360-6802

Other IC695ALG306

Available Revisions:

Confirm Your Revision Number

1C695ALG306 , GEFIC695ALG306 , CIMIC695ALG306

Specifications

 

Number of Channels

6/12 Individually isolated channels

Resolution

11.5-16 bits (see filter table)

Measuring method selectable per channel

Voltage: +/-50mV and +/-150mV

Thermocouple types: J, K, T, E, R, S, B, N and C

Integration time for 12 channels

Configurable from 15 msec to 120 msec.

Voltage Accuracy over temperature span

±0.1% of voltage span at 25 °C

±0.25% of span over temperature range

Thermocouple Input Types and Ranges

Thermocouple Type

Temperature Range

Type B

+300 to +1820

Type C

0 to +2315

Type E

-270 to +1000

Type J

-210 to +1200

Type K

-250 to +1372

Type N

-210 to +1300

Type R

0 to +1768

Type S

0 to +1768

Type T

-270 to +400

Voltage Input Ranges

Input Type

Voltage Range

-50mV to +50mV

-55.0 mV to +55.0 mV

-150mV to +150mV

-155.0 mV to +155.0 mV

Module temperature accuracy for thermocouple inputs over temperature span (2.3, 4, and 4.7 Hz filters), Does not include cold junction compensation or thermocouple tolerances.

Thermocouple Type & Range

+25°C

0°C to +60°C

Type J (-180C to +1200C)

±0.6°C

±2.3°C

Type J (-210C to -180C)

±0.8°C

±3.3°C

Type N (-160C to +1300C)

±1.0°C

±4.5°C

Type N (-210C to -160C)

±1.8°C

±8.0°C

Type T (-190C to +400C)

±0.9°C

±4.0°C

Type T (-270C to -190C)

±6.7°C

±18.0°C

Type K (-200C to +1372C)

±1.0°C

±4.0°C

Type K (-250C to -200C)

±5.1°C

±21.0°C

Type E (-200C to +1000C)

±0.6°C

±2.5°C

Type E (-270C to -200C)

±5.3°C

±14.0°C

Type S and R

±2.8°C

±11.5°C

Type C

±1.7°C

±7.0°C

Type B

±3.3°C

±20.0°C

Measurement Units

Degrees C or F, or Voltage

CJC measurement resolution

0.01° (C or F) for temperatures 0-60°C

CJC temperature accuracy

±1.5°C Typical (0-60°C), ±3.0°C Max (0-60°C)

Repeatability

0.05% of voltage span at a constant temperature over a 30-second period

Diagnostics reported to the controller

User configurable for Over Range, Under Range, High and Low Alarm, High- high and Low-low alarm, Open Circuit Detection, Positive and Negative Rate of Change alarm

Channel-to-channel crosstalk

70 dB minimum

 

Common Mode Rejection

2.3 Hz filter, 50/60Hz: 100 dB 4 Hz filter, 50Hz: 100 dB

4.7 Hz filter, 60Hz: 100 dB

Default or Hold Last State

Configurable per channel for Default to 0 or Hold Last State

Fault Reporting

Configurable per channel to enable or disable fault reporting for under or over range alarm, open circuit, rate of change alarm.

Rate of change

Configurable per channel to enable/disable and specify positive and negative rate of change alarms.

Channel Value Format

Configurable as 16-bit integer (in a 32-bit field) or 32-bit real number.

Backplane Power Requirements

3.3V IC695ALG306 = 400mA maximum

IC695ALG312 = 400mA maximum

5.0V IC695ALG306 = 225mA maximum

IC695ALG312 = 425mA maximum

Input Impedance

Voltage:  >=500k ohm

Power Dissipation within the module

IC695ALG306 = 2.5W max IC695ALG312 = 3.5W max

Isolation Voltage (Field to Backplane and Channel to channel)

(CJC inputs are not isolated from the backplane)

250VAC Continuous 1500VAC 1 minute

2550VDC 1 second

Normal Mode Noise Rejection

2.3 Hz filter, 50Hz/60Hz: 67dB

4 Hz filter, 50Hz/60Hz: 80dB 24 Hz filter, 50Hz/60Hz: 25dB

Module Filter settings, update times, rejection and resolution

Filter Frequency

(-3dB frequency)

Update Time (milliseconds)

Normal Mode Rejection at 50/60 Hz

2.3 Hz

120 (130 max)

67dB @ 50/60 Hz

4 Hz

70 (80 max)

80dB @ 50 Hz

4.7 Hz

60 (70 max)

80dB @ 60 Hz

24 Hz

20 (30 max)

25dB @ 50 Hz

28 Hz

15 (25 max)

25dB @ 60 Hz

Troubleshooting IC695ALG306

Troubleshooting information is available on IC695ALG306's website page; it also includes a datasheet user-manual and a wiring diagram.


Repair your IC695ALG306

PDF Supply can repair your IC695ALG306 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

Customer Questions and Answers


  • Question:  What is an IC695ALG306?  Answer:  The IC695ALG306 is a 6-Channel Isolated Thermocouple Input module from the GE Fanuc RX3i Series. 
  • Question:   What does IC695ALG306 provide?  Answer:  This module provides 6 isolated differential thermocouple input channels.
  • Question:   How are the individual channels congfigured?  Answer:  Each channel can be individually configured for inputs from:   
    • Thermocouple types: J, K, T, E, R, S, B, N, or C
    • Voltage: +/- 50mV
  • Question:  Where must IC695ALG306 be located?  Answer:  This module must be located in an RX3i Universal Backplane. 
  • Question:   With what kind of terminal blocks can IC695ALG306 be used?  Answer:  This module can be used with a Box-style (IC694TBB032), Extended Box-style (IC694TBB132), Spring-style (IC694TBS032), or Extended Spring-style (IC694TBS132) Terminal Block. 
  • Question:   What do extended terminal blocks provide?  Answer:  They provide the extra shroud depth needed for shielded wiring. 
  • Question:  What are some of the features of IC695ALG306?  Answer:
    • Completely software-configurable, no module jumpers to set
    • Thermocouple Linearization based on ITS-90
    • Supports hot removal and insertion (with system power applied)
    • 32-bit IEEE floating point or 16 bit integer (in 32 bit field) input data format selectable per channel
    • Temperature units selectable in degrees C and F
    • User scaling
    • Programmable notch filter from 2.3 Hz to 28 Hz per channel
    • Alarm dead band for high alarm, low alarm, high-high alarm, and low-low alarm by channel
    • Wire-off (open circuit) condition support for all inputs
    • Module fault status reporting (Watchdog, RAM Fail, Flash Fail)
    • Module identity and status reporting including LED status indicators
    • Supports Cold Junction Compensation (CJC) on Terminal Block (Cold Junction Sensor sold separately)
    • User offset for all channels including CJCs
    • Supports field upgrade of firmware application code
    • Optional CJC enable selections
    • Reports CJC temperatures as separate channels in Input Data
    • CJC update rate is fixed at 20 Hz
    • CJC filter setting fixed with first notch at 10 Hz, and 3dB input attenuation at 4.7 Hz
    • Terminal Block detection switch
  • Question:  What should I do if my IC695ALG306 is not working properly?  Answer:  Your IC695ALG306 may need repair

For more information on the IC695ALG306 6-Channel Isolated Thermocouple Input Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.

Release History

Version

Firmware Revision

Comments

IC695ALG306-EB IC695ALG312-EB

1.02

Hardware revision for improved manufacturability. No change in functions, performance or compatibility.

IC695ALG306-DB IC695ALG312-DB

1.02

Hardware revision to address component obsolescence. No change in functionality, performance, or compatibility.

IC695ALG306-CB IC695ALG312-CB

1.02

Improves accuracy of cold junction compensation and eliminates input glitches observed on some units. Also changes dual CJC scanning to revert to scanning a single operational CJC sensor in the event one of them fails instead of assuming 25°C for the failed sensor.

Modified Type K Thermocouple low-end range from -270 °C to -250 °C.

IC695ALG306-CA IC695ALG312-CA

1.00

Label change only. No change in functionality, performance or compatibility.

IC695ALG306-BA IC695ALG312-BA

1.00

Modified the terminal block detector switch to increase the size of the switch lever. The increased size of the switch lever allows additional tolerance to assure contact with the terminal block actuator.

IC695ALG306-AA IC695ALG312-AA

1.00

Initial Release

 

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180.

We can help you with your Revision specific needs.


Free Overnight delivery on orders over $500!

What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is sealed in the original manufacturer’s packaging with all sub-assemblies and documentation. May indicate older date code. Comes with a PDF Supply 3-year warranty.


Free Overnight delivery on orders over $500!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Supply packaging. May indicate older date code. Includes a PDF Supply 3 Year Warranty.


Free Overnight delivery on orders over $500!


What is Reconditioned?

Reconditioned products from PDF Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level and updated to the latest revision. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Supply 2-Year Warranty.

Free Overnight delivery on orders over $500!


What is a Verified Substitute?

A verified substitute new product is a "drop in" replacement designed with identical specifications as the OEM product. It will meet all electrical and dimensional charactertics at a substanstially reduced price.


Free Overnight delivery on orders over $500!


Download Lastest Documentation


Please visit this manufacturer's website to download the lastest manuals and datasheets.


Lowest Price Guarantee


We stand behind our prices with a lowest price guarantee. If you find a legacy GE PLC part advertised for less on an authorized GE PLC distributor website, simply contact us and send us a link to the lower advertised price. We will match that price and ship overnight FREE. The item must be in stock, in similar condition and be able to ship same day.

Free Shipping



FREE Overnight Delivery for Continental US orders over $500!

FREE Ground Delivery for Continental US orders under $500!

US orders placed Monday - Friday before 5pm EST will ship same day.

Canada/Mexico orders placed Monday - Friday before 3:30pm EST will ship same day.

International orders will ship the following business day.