The IC695ALG508 is an 8-Channel, Isolated, Resistance Temperature Detector (RTD) Input module from the GE Fanuc RX3i Series. The IC695ALG508 provides 8 isolated differential RTD input channels.  The module must be located in an RX3i Universal Backplane.  It requires an RX3i CPU firmware version 5.5 or later. See specifications for this unit on IC695ALG508's website page.

Technical Specifications


Module Type: RTD Input Module 
No of Inputs: 8 Differential Inputs 
Internal Power: 3.3V: 400mA;  5.1V: 200 mA
Number of Slots:  1 (single slot)
Range (ohms): 250/500/1000/2000/3000/4000 
Power Dissapation:  2.5W max

 

 

GE Intelligent Platforms / GE Fanuc GE RX3i PacSystem

SKU 2178069  UPC 0841134997206

Part Number: IC695ALG508 / ic695alg508
Mfr/Brand Name: GE Automation
Mfr Number: IC695ALG508 / ic695alg508
Type: Isolated RTD Input Module, 8 channels

Troubleshooting and Product Information for IC695ALG508

Download product information, troubleshooting guides and operation manuals to get your PLC operational.

New IC695ALG508
Price: $2,301
6 In Stock
1 Year Warranty

*Need a Specific Revision?

New Surplus IC695ALG508
Price: $1,888
2 In Stock
3 Year PDF Supply Warranty

*What is New Surplus?

Save
 18%
Reman IC695ALG508
Price: $1,128
1
In Stock

2 Year PDF Supply Warranty

*What is Remanufactured?

Save
 51%
Repair Your IC695ALG508
Price: $878
1 Year PDF Supply Warranty
Call For Assistance
1-800-360-6802

Other IC695ALG508

Available Revisions:

Confirm Your Revision Number

1C695ALG508 , GEFIC695ALG508 , CIMIC695ALG508

Specifications

Number of Channels

Eight

Measuring method selectable per channel

RTD/resistance: up to 4k ohms

RTD input types

          50, 100, 200, 500, and 1000 ohm Platinum 385 (IEC751 1983, Amend 2

1995; JISC 1604 1997)

          50, 100, 200, 500, and 1000 ohm Platinum 391.6  (JISC 1604: 1981)

          100 ohm, 200 ohm, 500 ohm, and 1000 ohm Nickel 618 (DIN 43760

Sept. 1987)

          120 ohm Nickel 672 (MINCO Application Aid #18, 5/90 Type Ni)

          10, 50, and 100 ohm Copper 426 (SAMA RC21-4-1966)

          604 ohm Nickel-Iron 518

Resistance Input Types

0-260, 0-525, 0-1050, 0-2100, 0-3150, 0-4200 ohms

Maximum RTD Lead Resistance

25 ohms each side, for a total of 50 ohms.

RTD and Resistance Input Types

Input Type

Ohms Supported

Excitation Current

Resistance

0-260, 0-525

0.717 mA

0-1050, 0-2100, 0-3150,

0-4200

0.238 mA

Platinum 385

50

1.175 mA

100

0.717 mA

200, 500, 1000

0.238 mA

Platinum 391.6

50

1.175 mA

100, 200

0.717 mA

500, 1000

0.238mA

Nickel 672

120

0.717 mA

Nickel 618

100,200

0.717 mA

500,1000

0.238 mA

Nickel-Iron 518

604

0.238 mA

Copper 426

10

1.654 mA

50, 100

1.175 mA

RTD Ranges

RTD Type

Low temp (C)

High temp (C)

Copper 426

-100.0

+260.0

Nickel 618

-100.0

+260.0

Nickel 672

-80.0

+260.0

Nickel-Iron 518

-100.0

+200.0

Platinum 385

-200.0

+850.0

Platinum 391.6

-200.0

+630.0

Temperature accuracy for inputs from 4-wire RTDs over temperature span (2.3, 4, and 4.7 Hz filters). This data does do not include the RTD sensor accuracy, which must be included when determining the overall system performance.

 

Three-wire RTDs have similar accuracies, but depend on the lead resistances being balanced.

 

For 2-wire RTDs, the lead resistance of the RTD contributes to the temperature error.

All tolerances double when 24Hz or 28Hz filters are used.

RTD Type

+25°C

0°C to +60°C

50 Ω Platinum 385

+/- 1.0°C

+/- 1.7°C

100 Ω Platinum 385

+/- 0.7°C

+/- 1.2°C

200 Ω Platinum 385

+/- 0.6°C

+/- 1.0°C

500 Ω Platinum 385

+/- 0.5°C

+/- 0.9°C

1000 Ω Platinum 385

+/- 0.5°C

+/- 0.9°C

100 Ω Platinum 391.6

+/- 0.6°C

+/- 1.1°C

200 Ω Platinum 391.6

+/- 0.5°C

+/- 0.9°C

500 Ω Platinum 391.6

+/- 0.4°C

+/- 0.8°C

1000 Ω Platinum 391.6

+/- 0.4°C

+/- 0.8°C

Nickel 672

+/- 0.3°C

+/- 0.5°C

Nickel 618:

+/- 0.3°C

+/- 0.5°C

Nickel-Iron 518

+/- 0.4°C

+/- 0.7°C

10 Ω Copper 426

+/- 1.0°C

+/- 2.4°C

50 Ω Copper 426

+/- 0.8°C

+/- 1.9°C

100 Ω Copper 426

+/- 0.8°C

+/- 1.9°C

 

Temperature accuracy for Resistance inputs

Resistance

+25°C

0°C to +60°C

250 ohms

+/- 0.25 Ω

+/- 0.35 Ω

500 ohms

+/- 0.3 Ω

+/- 0.45 Ω

1000 ohms

+/- 0.5 Ω

+/- 0.8 Ω

2000 ohms

+/- 0.9 Ω

+/- 1.5 Ω

3000 ohms

+/- 1.3 Ω

+/- 2.2 Ω

4000 ohms

+/- 1.7 Ω

+/- 2.9 Ω

Measurement Units

Degrees C or F, or Ohms

Repeatability

0.05% of span at a constant temperature over a 30-second period (0.1% for 10-ohm copper, 28Hz filter)

Diagnostics reported to the controller

User configurable for Over Range, Under Range, High and Low Alarm, High- high and Low-low alarm, Open Circuit Detection, Positive and Negative Rate of change alarm

Service Requests

Report module firmware revision

Hot-Swap

Supports removal and replacement under power as described in the RX3i System Manual (GFK-2314).

Calibration

Module should be field calibrated via the configuration software.

Channel-to-channel crosstalk

70 dB minimum at 120mS update rate for all channels

Common Mode Rejection

2.3 Hz filter, 50/60Hz: 100 dB for 4-wire, 90 dB for 2 and 3 wire 4 Hz filter, 50/60Hz: 100 dB

4.7 Hz filter, 50/60Hz: 100 dB

24 Hz, 28 Hz filter 50/60 Hz: 80 dB

Default or Hold Last State

For each of fault and disabled modes, the configuration will specify either to default a channel input to 0 or hold the last state of the input

Fault Reporting

The configuration can enable or disable fault reporting for either of under or over range alarm, open circuit, and rate of change alarm.

Rate of change

For each channel, the configuration can enable/disable and specify positive and negative rate of change alarms.

Channel Value Format

16-bit integer (in a 32-bit field) or 32-bit real number data for each channel.

Current Consumption

3.3V: 400mA; 5V: 200mA

Excitation Current

0.238mA-1.654 mA, depending on the input range.

Power Dissipation

2.5W max

Isolation Voltage

(Field to Backplane and Channel to Channel)

250VAC Continuous 1500VAC 1 minute

2550VDC 1 second

Normal Mode Noise Rejection

2.3 Hz filter, 50Hz: 67dB

2.3 Hz filter, 60Hz: 67dB

4 Hz filter, 50Hz: 80dB

4.7 Hz filter, 60Hz: 80dB

24 Hz filter, 50Hz: 25dB

28 Hz filter, 60Hz: 25dB

Filter Settings, Update Times, Rejection, and Resolution

Filter Frequency (-3dB frequency)

Update Time (milliseconds)

Normal Mode Rejection at  50/60 Hz

2.3 Hz

120 (130 max)

67dB @ 50/60 Hz

4 Hz

70 (80 max)

80dB @ 50 Hz

4.7 Hz

60 (70 max)

80dB @ 60 Hz

24 Hz

20 (30 max)

25dB @ 50 Hz

28 Hz

15 (25 max)

25dB @ 60 Hz

           

Troubleshooting IC695ALG508

Troubleshooting information is available on IC695ALG508's website page; it also includes a datasheet user-manual and a wiring diagram.


Repair your IC695ALG508

PDF Supply can repair your IC695ALG508 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

Customer Questions and Answers


  • Question:  What is an IC695ALG508?  Answer:  The IC695ALG508 is an 8-Channel, Isolated, Resistance Temperature Detector Input module from the GE Fanuc RX3i Series.
  • Question:  What does IC695ALG508 do?   Answer:  This module provides 8, isolated differential RTD input channels. 
  • Question:  The configuration for each channel can be what?   Answer:
    • RTD Inputs:
      • 50, 100, 200, 500, and 1000 ohm Pt 385
      • 50, 100, 200, 500, and 1000 ohm Pt 391.6
      • 100, 200, 500, and 1000 ohm Ni 618
      • 120 ohm Ni 672
      • 604 ohm NiFe 518
      • 10, 50, and 100 ohm Cu 426
    • Resistance Inputs:
      • 250, 500, 1000, 2000, 3000, and 4000 Ohms
  • Question:  What is one thing you will need to test IC695ALG508?   Answer:  You will need a high-density terminal strip (IC694TBB032). 
  • Question:  What do I need to know about the high-density terminal strip?   Answer:  You should make sure the lever on it is in the upright-most position, which will turn the LED green to let you know you are fully connected. If it is red or you don't have a light, then you know something is wrong. 
  • Question:  What am I expecting to see when I probe each channel with the resistor?   Answer:  You should expect to see the same number because you should have set them all up with the same configuration. 
  • Question:  Why is this important?   Answer:  It is important because if there is an issue with a channel not reading the same number, then you will know and be able to check into that channel. 
  • Question: What should I do if my IC695ALG508 is not working properly?   Answer:  Your IC695ALG508 may need repair

For more information on the IC695ALG508 8-Channel, Isolated, Resistance Temperature Detector Input Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.

Release History

 

Version

Firmware Revision

Comments

IC695ALG508-DB

2.00

New HW and FW design to address obsolescence issue and meet RoHS compliance.

IC695ALG508-CA

1.00

Label change only. No change in functionality, performance or compatibility.

 

IC695ALG508-BA

 

1.00

Modified the terminal block detector switch to increase the size of the switch lever. The increased size of the switch lever allows additional tolerance to assure contact with the terminal block actuator.

IC695ALG508-AA

1.00

Initial Release

 

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180.

We can help you with your Revision specific needs.


Free Overnight delivery on orders over $500!

What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is sealed in the original manufacturer’s packaging with all sub-assemblies and documentation. May indicate older date code. Comes with a PDF Supply 3-year warranty.


Free Overnight delivery on orders over $500!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Supply packaging. May indicate older date code. Includes a PDF Supply 3 Year Warranty.


Free Overnight delivery on orders over $500!


What is Reconditioned?

Reconditioned products from PDF Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level and updated to the latest revision. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Supply 2-Year Warranty.

Free Overnight delivery on orders over $500!


What is a Verified Substitute?

A verified substitute new product is a "drop in" replacement designed with identical specifications as the OEM product. It will meet all electrical and dimensional charactertics at a substanstially reduced price.


Free Overnight delivery on orders over $500!


Download Lastest Documentation


Please visit this manufacturer's website to download the lastest manuals and datasheets.


Lowest Price Guarantee


We stand behind our prices with a lowest price guarantee. If you find a legacy GE PLC part advertised for less on an authorized GE PLC distributor website, simply contact us and send us a link to the lower advertised price. We will match that price and ship overnight FREE. The item must be in stock, in similar condition and be able to ship same day.

Free Shipping



FREE Overnight Delivery for Continental US orders over $500!

FREE Ground Delivery for Continental US orders under $500!

US orders placed Monday - Friday before 5pm EST will ship same day.

Canada/Mexico orders placed Monday - Friday before 3:30pm EST will ship same day.

International orders will ship the following business day.