IC695ALG628

Rated 4.9/5 Based on 8 ratings.

Rate your purchase of the IC695ALG628

IC693PWR324 Image of IC695ALG628 IC695ALG628 Analog Input HART module, 8 channels single ended, 4 channels differential IC695A IC695A

SKU 2178226  UPC 0101254208652

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!


New

$1312

2 In Stock

2 Year warranty

*Need a Specific Revision?

"Factory Sealed"

New Surplus

$946

Save $366

5 In Stock

3 Year warranty

*What is New Surplus?

"Like New Condition"

Remanufactured

$695

Save $617

1 In Stock

2 Year warranty

*What is Remanufactured?

"Avg. Repair - 2 Days"

Repair Service

$485

Save $827

Fast or Free!

2 Year warranty

*What is Fast Repair?

Other Available Revisions for the IC695ALG628 -AA-BA-CA-DA-EA-FB-GB-HC-HDLT

Product Description


The IC695ALG628 is an 8/4 Channel, Non-Isolated, Differential, Voltage/Current, HART, Analog Input module from the GE Fanuc RX3i Series.   This Module provides 8 single-ended or 4 differential inputs.  Module IC695ALG628 has 2 internal HART modems.  See specifications for this unit on IC695ALG628's website page.

Technical Specifications


Module Type: Analog Input w/HART comms
Number of Inputs:   8 single-ended or 4 differential
Internal Power: 3.3V: 600mA;  5V: 450 mA
Number of Slots: 1 (single slot)
Current Range: 0-20 mA, 4-20 mA, +/-20 mA
Voltage Range: +/-10V, 0-10V, +/-5V, 0-5V,1-5V 

 

 

Technical Information

Specifications

Input Ranges

Current: 0 to 20mA, 4 to 20mA, ±20mA Voltage: ±10V, 0 to 10V, ±5V, 0 to 5V, 1 to 5V

Backplane Power Requirements

ALG608: ALG616: ALG626:

ALG628:

200 mA maximum @ 5.0V +5% / -2.5%,

200 mA maximum @ 3.3V +5% / -3%

350 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

400 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

260 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

 

Power Dissipation within Module

IC695ALG608: IC695ALG626:

2.58 W maximum; IC695ALG616:

4.50 W maximum; IC695ALG628:

4.25  W maximum

2.83  W maximum

Thermal Derating

IC695ALG608 and ALG616: no derating IC695ALG628: no derating

Module IC695ALG626 has no thermal derating in voltage mode. For thermal derating for module IC695ALG626 in current mode, refer to page 4.

Resolution

24-bit ADC converted to Floating Point or Integer

Input Data Format

Configurable as floating point IEEE 32-bit or 16-bit integer in a 32-bit field

Filter Options

8Hz, 12Hz, 16Hz, 40Hz, 200Hz,  500Hz

HART Communications

Version 5.0 HART protocol supported on modules IC695ALG626 and IC695ALG628.

Input Impedance

>100 k voltage inputs

Current Input Resistance

249  ±1%

Open Circuit Detection time

1 second maximum

Overvoltage

±60 VDC continuous, maximum

Overcurrent

±28mA continuous, maximum

Normal Mode Noise Rejection in dB

 

At 50Hz

At 60Hz

8 Hz filter

85

85

12 Hz filter

85

85

16 Hz filter

35

62

40 Hz filter

3

6

200 Hz filter

0

0

500 Hz

0

0

Common Mode Noise Rejection

120dB minimum @ 50/60 Hz with 8 Hz filter 110dB minimum @ 50/60 Hz with 12 Hz  filter

Channel-Channel DC Crosstalk

-80 dB minimum (single ended  mode)

-80 dB minimum (differential mode, grounded common)

-60 dB minimum (differential mode, floating  common)

Isolation Voltage terminal block to

backplane/chassis

Opto-isolated,  transformer isolated

250 VAC continuous/1500 VAC for 1 minute

           

 

 

Analog Module Scan Time (in milliseconds)

 

Configured Filter

 

 

8 Hz filter

12 Hz filter

16 Hz filter

40 Hz filter

200 Hz filter

500 Hz filter [with filtering and rate detection disabled]

Configured Filter

 

 

8 Hz filter

12 Hz filter

16 Hz filter

40 Hz filter

200 Hz filter

500 Hz filter

[with filtering and rate

detection disabled]

The module scan for analog signals can consist of up to four acquisition cycles. Each cycle includes a specific set of channels. Total Scan Time depends on the number of acquisition cycles

in the scan, the configured filter option, and whether channels are analog or HART.

Number of Acquisition Cycles in the Scan (IC695ALG608/616/626/628- Ex and earlier)

1

2

3

4

Analog

HART

Analog

HART

Analog

HART

Analog

HART

121

128

241

254

362

380

482

506

81

88

161

174

242

260

322

346

61

68

121

134

182

200

242

266

21

28

41

54

62

80

82

106

5

12

9

22

14

32

18

42

3

N/A

5

[6]

N/A

7

[9]

N/A

9

[12]

N/A

Number of Acquisition Cycles in the Scan (C695ALG608/616/626/628- Fx and later)

1

2

3

4

Analog

HART

Analog

HART

Analog

HART

Analog

HART

122

124

247

248

367

375

494

500

82

85

164

169

247

255

329

337

62

65

127

130

188

191

252

258

25

26

50

50

76

72

100

93

6

12

12

17

19

24

26

32

3

N/A

7

[6]

N/A

11

[9]

N/A

15

[12]

N/A

HART Data Scan Time (in seconds)

The HART data scan can consist of up to four acquisition cycles (similar but asynchronous to the analog scan time). Each cycle includes a specific set of channels. Total HART scan time depends on the number of channels enabled for HART within a specific set of channels, number of retries,

enabling/disabling of slot variables, and use and configuration settings of pass-thru commands.

Channels in Group Enabled for HART:

Each HART Data channel updates every:

One

0.7 second (typical)

Two

1.9 seconds (typical)

Three

3.0 seconds (typical)

Four

4.0 seconds (typical)

Calibrated   Accuracy In the presence of severe  RF interference

(IC 801-3, 10V/M),

accuracy may be degraded by ±1.5% of range.

From 13°C – 33°C:

±5V, ±10V, ± 20 mA: 0.05%  of range.

0 to 10V, 0 to 5V, 1 to 5V, 0 to 20 mA:   0.1% of range.

4 to 20 mA: 0.125%  of range.

From 0°C – 60°C:

0 to 10V, 0 to 5V, 1 to 5V: 0.2%  of range.

0 to 20 mA: 0.25%  of range.

4 to 20 mA: 0.3125%  of range.

±5V, ±10V: 0.1% ±20 mA: 0.125%  of range.

Calibration Interval

12 months typical to meet accuracy specifications over time. Offset can be applied as a periodic calibration adjustment.

 

Troubleshooting

Troubleshooting IC695ALG628

Troubleshooting information is available on IC695ALG628's website page; it also includes a datasheet user-manual and a wiring diagram.

 

Repair your IC695ALG628

PDF Supply can repair your IC695ALG628 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

Customer Questions and Answers


  • Question:  What is an IC695ALG628?  Answer:  The IC695ALG628 is an 8/4 Channel, Non-Isolated, Differential, Voltage/Current, HART, Analog Input module from the GE Fanuc RX3i Series. 
  • Question:  What does IC695ALG628 provide?  Answer:  This module provides 8 single-ended or 4 differential input channels. 
  • Question:  What does IC695ALG628 feature?  Answer:  This module features HART version 5.0 communications capability on each channel. 
  • Question:  How many HART modems does IC695ALG628 have?  Answer:  This module has 2 internal HART modems. 
  • Question:  What happens in single-ended mode?  Answer:  In single-ended mode, 4 single-ended channels are multiplexed into each HART modem.
  • Question:  What happens in differential mode?  Answer:  In differential mode, 2 differential channels are multiplexed into each HART modem. 
  • Question:  For configuration, at what ranges can the analog input channels be set?  Answer:
    • Current: 0 to 20 mA, 4 to 20 mA, +/- 20 mA
    • Voltage: +/- 10 V, 0 to 10 V, +/- 5 V, 0 to 5 V, 1 to 5 V
  • Question:  For channels that use HART communications, what must the configuration be?  Answer:  It must be in the 4-20mA range.
  • Question:  What should I do if my IC695ALG628 is not working properly?  Answer:  Your IC695ALG628 may need repair

For more information on the IC695ALG628 8/4 Channel, Non-Isolated, Differential, Voltage/Current, HART, Analog Input Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.

Release History

 

Version

Firmware Revision

 

Description

IC695ALG608-HD, IC695ALG616-HD, IC695ALG626-HD,   IC695ALG628-HD

2.08

Provided resolution to issues introduced in firmware version 2.00 (- FB):

  • Point fault not set on open wire detect
  • [F] and [NF] contacts operate incorrectly
  • [HA] and [LA] contacts operate incorrectly on new HW platform ALG628 & ALG626
  • [HA] and [LA] contacts operate incorrectly on new HW platform ALG608 & ALG616

IC695ALG608-HC, IC695ALG626-HC, IC695ALG628-HC

2.06

IC695ALG626-FB,  IC695ALG628-FB,  IC695ALG608-FB  (and later)

provides the wrong device ID to  RX3i PNS (IC695PNS001)  and

IC695CEP001 modules causing a configuration mismatch.

IC695ALG608-GB, IC695ALG616-GB, IC695ALG626-GB,   IC695ALG628-GB

2.00

  • Updated hardware to address a power-up issue in systems using more than three modules in a single backplane.

IC695ALG608-FB, IC695ALG616-FB, IC695ALG626-FB, IC695ALG628-FB

2.00

  • Changed processor due to obsolescence.
  • Modified the 16-bit Integer input value Software Filtering to improve accuracy
  • Modified error bit handling on odd channels when over voltage condition occurs to be more consistent with even channels.
  • Added support for determining module serial number and date of manufacture via Proficy* Machine Edition connection.

IC695ALG608-EA, IC695ALG616-EA, IC695ALG626-EA,   IC695ALG628-EA

1.01

Label change only. No change in functionality, performance or compatibility.

IC695ALG608-DA, IC695ALG616-DA, IC695ALG626-DA,   IC695ALG628-DA

1.01

Modified the terminal block detector switch to increase the size of the switch lever. The increased size of the switch lever allows additional tolerance to assure contact with the terminal block actuator.

IC695ALG608-CA, IC695ALG616-CA, IC695ALG626-CA, IC695ALG628-CA

1.01

Updated Hardware

 

 

Version

Firmware Revision

 

Description

IC695ALG608-BA, IC695ALG616-BA, IC695ALG626-BA,   IC695ALG628-BA

1.01

Updated Hardware

IC695ALG608-AA, IC695ALG616-AA, IC695ALG626-AA,  IC695ALG628-AA

1.01

Initial Release

 

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.
All online orders placed before 4:30 PM EST “SHIPS SAME DAY FREE!" World’s largest warehouse of Factory Sealed GE 90-30 PLC, GENIUS I/O and RX7i PACSystem.highlight_off

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.