PDF Electric and Supply

1-800-360-6802
1-919-535-3180
sales@pdfsupply.com

IC695ALG628

Buy NowIC695ALG628
IC695ALG628
IC695ALG628 Wiring

Rated 4.9/5 based on 8 ratings.
  • IC695ALG628
  • IC695ALG628 Wiring

Product Description


The IC695ALG628 is an 8/4 Channel, Non-Isolated, Differential, Voltage/Current, HART, Analog Input module from the GE Fanuc RX3i Series.   This Module provides 8 single-ended or 4 differential inputs.  Module IC695ALG628 has 2 internal HART modems.  See specifications for this unit on IC695ALG628's website page.

Technical Specifications


Module Type: Analog Input w/HART comms
Number of Inputs:   8 single-ended or 4 differential
Internal Power: 3.3V: 600mA;  5V: 450 mA
Number of Slots: 1 (single slot)
Current Range: 0-20 mA, 4-20 mA, +/-20 mA
Voltage Range: +/-10V, 0-10V, +/-5V, 0-5V,1-5V 

 

 

GE Intelligent Platforms / GE Fanuc GE RX3i PacSystem

SKU 2178226  UPC 0101254208652

Part Number: IC695ALG628 / ic695alg628
Mfr/Brand Name: GE Automation
Mfr Number: IC695ALG628 / ic695alg628
Type: Analog Input Module, 8/4 Channel, Voltage/Current, HART

Troubleshooting and Product Information for IC695ALG628

Download product information, troubleshooting guides and operation manuals to get your PLC operational.

New IC695ALG628
Price: $1,274
5 In Stock
1 Year Warranty

*Need a Specific Revision?

New Surplus IC695ALG628
Price: $892
2 In Stock
3 Year PDF Supply Warranty

*What is New Surplus?

Save
 30%
Repair Your IC695ALG628
Price: $485
1 Year PDF Supply Warranty
Call For Assistance
1-800-360-6802

Other IC695ALG628

Available Revisions:

Confirm Your Revision Number

1C695ALG628 , GEFIC695ALG628 , CIMIC695ALG628

Specifications

Input Ranges

Current: 0 to 20mA, 4 to 20mA, ±20mA Voltage: ±10V, 0 to 10V, ±5V, 0 to 5V, 1 to 5V

Backplane Power Requirements

ALG608: ALG616: ALG626:

ALG628:

200 mA maximum @ 5.0V +5% / -2.5%,

200 mA maximum @ 3.3V +5% / -3%

350 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

400 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

260 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

 

Power Dissipation within Module

IC695ALG608: IC695ALG626:

2.58 W maximum; IC695ALG616:

4.50 W maximum; IC695ALG628:

4.25  W maximum

2.83  W maximum

Thermal Derating

IC695ALG608 and ALG616: no derating IC695ALG628: no derating

Module IC695ALG626 has no thermal derating in voltage mode. For thermal derating for module IC695ALG626 in current mode, refer to page 4.

Resolution

24-bit ADC converted to Floating Point or Integer

Input Data Format

Configurable as floating point IEEE 32-bit or 16-bit integer in a 32-bit field

Filter Options

8Hz, 12Hz, 16Hz, 40Hz, 200Hz,  500Hz

HART Communications

Version 5.0 HART protocol supported on modules IC695ALG626 and IC695ALG628.

Input Impedance

>100 k voltage inputs

Current Input Resistance

249 ±1%

Open Circuit Detection time

1 second maximum

Overvoltage

±60 VDC continuous, maximum

Overcurrent

±28mA continuous, maximum

Normal Mode Noise Rejection in dB

 

At 50Hz

At 60Hz

8 Hz filter

85

85

12 Hz filter

85

85

16 Hz filter

35

62

40 Hz filter

3

6

200 Hz filter

0

0

500 Hz

0

0

Common Mode Noise Rejection

120dB minimum @ 50/60 Hz with 8 Hz filter 110dB minimum @ 50/60 Hz with 12 Hz  filter

Channel-Channel DC Crosstalk

-80 dB minimum (single ended  mode)

-80 dB minimum (differential mode, grounded common)

-60 dB minimum (differential mode, floating  common)

Isolation Voltage terminal block to

backplane/chassis

Opto-isolated,  transformer isolated

250 VAC continuous/1500 VAC for 1 minute

           

 

 

Analog Module Scan Time (in milliseconds)

 

Configured Filter

 

 

8 Hz filter

12 Hz filter

16 Hz filter

40 Hz filter

200 Hz filter

500 Hz filter [with filtering and rate detection disabled]

Configured Filter

 

 

8 Hz filter

12 Hz filter

16 Hz filter

40 Hz filter

200 Hz filter

500 Hz filter

[with filtering and rate

detection disabled]

The module scan for analog signals can consist of up to four acquisition cycles. Each cycle includes a specific set of channels. Total Scan Time depends on the number of acquisition cycles

in the scan, the configured filter option, and whether channels are analog or HART.

Number of Acquisition Cycles in the Scan (IC695ALG608/616/626/628- Ex and earlier)

1

2

3

4

Analog

HART

Analog

HART

Analog

HART

Analog

HART

121

128

241

254

362

380

482

506

81

88

161

174

242

260

322

346

61

68

121

134

182

200

242

266

21

28

41

54

62

80

82

106

5

12

9

22

14

32

18

42

3

N/A

5

[6]

N/A

7

[9]

N/A

9

[12]

N/A

Number of Acquisition Cycles in the Scan (C695ALG608/616/626/628- Fx and later)

1

2

3

4

Analog

HART

Analog

HART

Analog

HART

Analog

HART

122

124

247

248

367

375

494

500

82

85

164

169

247

255

329

337

62

65

127

130

188

191

252

258

25

26

50

50

76

72

100

93

6

12

12

17

19

24

26

32

3

N/A

7

[6]

N/A

11

[9]

N/A

15

[12]

N/A

HART Data Scan Time (in seconds)

The HART data scan can consist of up to four acquisition cycles (similar but asynchronous to the analog scan time). Each cycle includes a specific set of channels. Total HART scan time depends on the number of channels enabled for HART within a specific set of channels, number of retries,

enabling/disabling of slot variables, and use and configuration settings of pass-thru commands.

Channels in Group Enabled for HART:

Each HART Data channel updates every:

One

0.7 second (typical)

Two

1.9 seconds (typical)

Three

3.0 seconds (typical)

Four

4.0 seconds (typical)

Calibrated   Accuracy In the presence of severe  RF interference

(IC 801-3, 10V/M),

accuracy may be degraded by ±1.5% of range.

From 13°C – 33°C:

±5V, ±10V, ± 20 mA: 0.05%  of range.

0 to 10V, 0 to 5V, 1 to 5V, 0 to 20 mA:   0.1% of range.

4 to 20 mA: 0.125%  of range.

From 0°C – 60°C:

0 to 10V, 0 to 5V, 1 to 5V: 0.2%  of range.

0 to 20 mA: 0.25%  of range.

4 to 20 mA: 0.3125%  of range.

±5V, ±10V: 0.1% ±20 mA: 0.125%  of range.

Calibration Interval

12 months typical to meet accuracy specifications over time. Offset can be applied as a periodic calibration adjustment.

 

Troubleshooting IC695ALG628

Troubleshooting information is available on IC695ALG628's website page; it also includes a datasheet user-manual and a wiring diagram.


Repair your IC695ALG628

PDF Supply can repair your IC695ALG628 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

Customer Questions and Answers


  • Question:  What is an IC695ALG628?  Answer:  The IC695ALG628 is an 8/4 Channel, Non-Isolated, Differential, Voltage/Current, HART, Analog Input module from the GE Fanuc RX3i Series. 
  • Question:  What does IC695ALG628 provide?  Answer:  This module provides 8 single-ended or 4 differential input channels. 
  • Question:  What does IC695ALG628 feature?  Answer:  This module features HART version 5.0 communications capability on each channel. 
  • Question:  How many HART modems does IC695ALG628 have?  Answer:  This module has 2 internal HART modems. 
  • Question:  What happens in single-ended mode?  Answer:  In single-ended mode, 4 single-ended channels are multiplexed into each HART modem.
  • Question:  What happens in differential mode?  Answer:  In differential mode, 2 differential channels are multiplexed into each HART modem. 
  • Question:  For configuration, at what ranges can the analog input channels be set?  Answer:
    • Current: 0 to 20 mA, 4 to 20 mA, +/- 20 mA
    • Voltage: +/- 10 V, 0 to 10 V, +/- 5 V, 0 to 5 V, 1 to 5 V
  • Question:  For channels that use HART communications, what must the configuration be?  Answer:  It must be in the 4-20mA range.
  • Question:  What should I do if my IC695ALG628 is not working properly?  Answer:  Your IC695ALG628 may need repair

For more information on the IC695ALG628 8/4 Channel, Non-Isolated, Differential, Voltage/Current, HART, Analog Input Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.

Release History

 

Version

Firmware Revision

 

Description

IC695ALG608-HD, IC695ALG616-HD, IC695ALG626-HD,   IC695ALG628-HD

2.08

Provided resolution to issues introduced in firmware version 2.00 (- FB):

  • Point fault not set on open wire detect
  • [F] and [NF] contacts operate incorrectly
  • [HA] and [LA] contacts operate incorrectly on new HW platform ALG628 & ALG626
  • [HA] and [LA] contacts operate incorrectly on new HW platform ALG608 & ALG616

IC695ALG608-HC, IC695ALG626-HC, IC695ALG628-HC

2.06

IC695ALG626-FB,  IC695ALG628-FB,  IC695ALG608-FB  (and later)

provides the wrong device ID to  RX3i PNS (IC695PNS001)  and

IC695CEP001 modules causing a configuration mismatch.

IC695ALG608-GB, IC695ALG616-GB, IC695ALG626-GB,   IC695ALG628-GB

2.00

  • Updated hardware to address a power-up issue in systems using more than three modules in a single backplane.

IC695ALG608-FB, IC695ALG616-FB, IC695ALG626-FB, IC695ALG628-FB

2.00

  • Changed processor due to obsolescence.
  • Modified the 16-bit Integer input value Software Filtering to improve accuracy
  • Modified error bit handling on odd channels when over voltage condition occurs to be more consistent with even channels.
  • Added support for determining module serial number and date of manufacture via Proficy* Machine Edition connection.

IC695ALG608-EA, IC695ALG616-EA, IC695ALG626-EA,   IC695ALG628-EA

1.01

Label change only. No change in functionality, performance or compatibility.

IC695ALG608-DA, IC695ALG616-DA, IC695ALG626-DA,   IC695ALG628-DA

1.01

Modified the terminal block detector switch to increase the size of the switch lever. The increased size of the switch lever allows additional tolerance to assure contact with the terminal block actuator.

IC695ALG608-CA, IC695ALG616-CA, IC695ALG626-CA, IC695ALG628-CA

1.01

Updated Hardware

 

 

Version

Firmware Revision

 

Description

IC695ALG608-BA, IC695ALG616-BA, IC695ALG626-BA,   IC695ALG628-BA

1.01

Updated Hardware

IC695ALG608-AA, IC695ALG616-AA, IC695ALG626-AA,  IC695ALG628-AA

1.01

Initial Release

 

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180.

We can help you with your Revision specific needs.


Free Overnight delivery on orders over $500!

What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is sealed in the original manufacturer’s packaging with all sub-assemblies and documentation. May indicate older date code. Comes with a PDF Supply 3-year warranty.


Free Overnight delivery on orders over $500!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Supply packaging. May indicate older date code. Includes a PDF Supply 3 Year Warranty.


Free Overnight delivery on orders over $500!


What is Reconditioned?

Reconditioned products from PDF Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level and updated to the latest revision. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Supply 2-Year Warranty.

Free Overnight delivery on orders over $500!


What is a Verified Substitute?

A verified substitute new product is a "drop in" replacement designed with identical specifications as the OEM product. It will meet all electrical and dimensional charactertics at a substanstially reduced price.


Free Overnight delivery on orders over $500!


Download Lastest Documentation


Please visit this manufacturer's website to download the lastest manuals and datasheets.


Lowest Price Guarantee


We stand behind our prices with a lowest price guarantee. If you find a legacy GE PLC part advertised for less on an authorized GE PLC distributor website, simply contact us and send us a link to the lower advertised price. We will match that price and ship overnight FREE. The item must be in stock, in similar condition and be able to ship same day.

Free Shipping



FREE Overnight Delivery for Continental US orders over $500!

FREE Ground Delivery for Continental US orders under $500!

US orders placed Monday - Friday before 5pm EST will ship same day.

Canada/Mexico orders placed Monday - Friday before 3:30pm EST will ship same day.

International orders will ship the following business day.