Dual Core 1G Controller CPU Requires and Energy PAC for RAM memory backup with no power to system. |

Dual Core 1G Controller CPU Requires and Energy PAC for RAM memory backup with no power to system. | Dual Core 1G Controller CPU Requires and Energy PAC for RAM memory backup with no power to system. | IC695CPE330

SKU 2170101  UPC 0799705806740

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!

New

$5787

7 In Stock

2 Year warranty

*Need a Specific Revision?

New Surplus

$4550

Save $1,237

7 In Stock

3 Year warranty

*What is New Surplus?

Remanufactured

$2754

Save $3,033

3 In Stock

2 Year warranty

*What is Remanufactured?

Repair Service

$2450

Save $3,337

Fast or Free!

2 Year warranty

*What is Fast Repair?

Product Description


The IC695CPE330 is a programmable CPU with Ethernet connectivity in the GE Fanuc PACSystems RX3i Series. To program and configure IC695CPE330, you typically use Proficy Machine Edition software. As a user, you can choose any of several different languages in which to program the controller. Depending on what you want to do with industrial-scale automation, you can program in Ladder Diagram, Function Block Diagram, Structured Text, or C. You can also create Symbolic Variables confidently.

 

The module is a controller that supports other RX3i I/O and Intelligent Option modules. Its CPU can accommodate up to 512 program blocks, each of which can have a capacity of as much as 128 KB.

 

IC695CPE330 ships with 64 MB of user memory, 64 MB of program memory, and a pair of independent high-speed Ethernet LANs labeled LAN1 and LAN2. LAN1 uses a dedicated RJ-45 (sometimes written RJ45) connector. LAN2 uses a pair of internally switched connectors. Both LANs are served by dedicated microprocessors and network interface controllers, so that the involved Ethernet functions independently of the controller logic and I/O scanning. Ethernet interfaces on the controller sense data rates, communications modes, and cabling arrangements automatically.

 

Each of the two LANs can run up to 48 SRTP (Secure Real-time Transport Protocol) Server connections simultaneously. The controller supports three different serial protocols: Modbus RTU Slave, Serial I/O, and SNP Slave.

 

Cutouts in the controller's metal housing and labels on its faceplate make connectivity and cabling options readily apparent. The controller is designed to synchronize data while enabling multi-tier communications. It also allows you to transfer data to and from USB 2.0 removable data storage devices.

Technical Specifications


Processing Speed: 1 GHz
CPU Memory: 64 Mbytes
Floating Point: Yes
Ethernet Interfaces:   2 (LAN 1 & LAN 2)
Serial Protocols: Modbus RTU Slave, SNP Slave, Serial I/O
Embedded Comms: RJ-45

 

Technical Information

CPU Features:
  • RX3i Hot Standby Redundancy CPU with support for PROFINET I/O using IC695PNC001 PROFINET Controllers.
  • RX3i Hot Standby Redundancy with Ethernet (EGD) & Genius I/O
  • Simplex PROFINET I/O Controller with support for up to 32 I/O devices and update rates of 1 512ms. I/O device update rates of 8ms and faster are possible with 16 or fewer devices. When there are more than 16 devices configured, update rates of 16ms and higher are available.
  • Supports two independent 10/100/1000 Ethernet LANs. LAN1 attaches via the dedicated (upper) RJ- 45 connector. LAN2 attaches via the lower pair of internally-switched RJ-45 connectors.
  • Achilles Level 2 Communications Certification1
  • The embedded Ethernet interface is supported by a dedicated microprocessor core. This dedicated processing capability permits the CPU to support these two LANs with:
    • up to 48 simultaneous SRTP Server connections,
    • up to 16 simultaneous Modbus®/TCP Server connections.
    • 32 clients are permitted; each may be SRTP or Modbus/SRTP.
    • OPC UA Server with support for up to 5 concurrent sessions with up to 10 concurrent variable subscriptions and up to 12,500 variables;
    • up to 255 simultaneous Class 1 Ethernet Global Data (EGD) exchanges;
    • two independent Redundant IP addresses, one for each of the embedded Ethernet LANs.
  • Embedded SNTP Client allows synchronization of the high-resolution Time of Day Clock to an SNTP network time server.
  • Optional Energy Pack, IC695ACC402, allows CPE330 to instantly save user memory to non-volatile storage in the event of loss of power.

 

* Indicates a trademark of General Electric Company and/or its subsidiaries. All other trademarks are the property of their respective owners. Copyright © 2015 - 2016 General Electric Company. All Rights Reserved.

1 Achilles Level 2 Communication Certification available in CPE330 R8.80 and later.

Troubleshooting

Troubleshooting IC695CPE330

Troubleshooting information is available on IC695CPE330's website page; it also includes a datasheet, a usermanual, and a wiring diagram.

 

Repair your IC695CPE330

PDF Supply can repair your IC695CPE330 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

 

Error 8544 Flash Operation Failed

Description
One of the scenario to generate this error is trying to download a different IP address for a ethernet card to flash.
For example, PLC is running well with the ethernet card IP address 192.168.0.10. Then customer wants to change the IP to 10.0.0.10.  After changing the new IP (10.0.0.10) in HW configuration first, and connecting with the PLC via the original IP (192.168.0.10), the customer choose to download all configuration to flash directly.
Then the error 8544 will occur, at the same time, PME will lose connection with PLC.

Resolution
If the customer wants to revise the IP address for a running system, there are 2 ways to complete that.

The first way, set the new IP address for the ethernet card as a new module.

  • For the module, which could support Set Temporary IP function, like IC695CPE330/IC695ETM001.  Input the MAC address attached in ethernet card into Set Temporary IP Address tool in PME to set the new IP.
  • For the module, which could not support Set Temporary IP function, like IC695CPE305/310. Using the Serial port on the module to configure the new IP address, and download to CPU via serial port. Or if there is available ETM module installed in the same rack, the new IP could also be written in via this separate ethernet card.


The Second way, download the new IP address to CPU via PME.

  1. Configuring the new IP address (10.0.0.10)for ethernet card in HW configuration in PME;
  2. Connect with CPU via the original IP address(192.168.0.10);
  3. Download the configuration to Ram; (if the CPU is running, we need to stop it first)
  4. After downloading completed, the connection between PME and CPU will lose;
  5. Revising the IP address as the new one (10.0.0.10)in Target properties;
  6. Revising the PC IP address to the same network with the new IP address, for example, 10.0.0.100;
  7. Connect with CPU via the new IP (10.0.0.10) again;
  8. Right click Target, choose Online Commands->Flash/EEProm, then select Operation Write, click OK.


Then in Feedback Zone, it will show The Flash/EEPROM operation completed successfully. That means the new IP address has been written to flash successfully.

 

Customer Questions and Answers


  • Question:  What is an IC695CPE330?  Answer:  The IC695CPE330 is a Central Processing Unit with Ethernet from the GE Fanuc RX3i Series. 
  • Question:  With what is IC695CPE330 equipped?  Answer:  It is equipped with a 1 GHz dual-core microprocessor, 64 Mbytes of built-in program memory and 2 independent high-speed Ethernet interfaces. 
  • Question:  What does IC695CPE330 do?  Answer:  It is ideally suited for multi-tier communications and for synchronizing large amounts of data. 
  • Question:  Over what software is IC695CPE330 programmed and configured?  Answer:  The programming and configuration of IC695CPE330 is completed over Ethernet via GE's Proficy Machine Edition (PME) software. 
  • Question:  Where does IC695CPE330 reside and what does it support?  Answer:  It resides in the RX3i main rack and supports all RX3i I/O and Intelligent Option modules, up to 32K I/O points.
  • Question:  How much user memory does IC695CPE330 contain?  Answer:  64 Mbytes
  • Question:  What does the optional energy pack allow IC695CPE330 to do?  Answer:  It allows the CPU to save user memory to non-volatile storage in the event of a loss of power.
  • Question:  What should I do if my IC695CPE330 is not working properly?  Answer:  Your IC695CPE330 may need repair.

For more information on the IC695CPE330 Central Processing Unit with Ethernet of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.

 

Release History

Catalog Number

 

Bundled w/ACC402

Energy Pack

 

 

Date

Firmware Version (Build Number)

Field Upgradeable

Not Field Upgradeable

Primary

OS

Loader

BOC

FPGA

Primary

µController Primary

ACC402

EP Base

µController Boot

BIOS

IC695CPE330- ABAL IC695CPE330CA-

ABAL

 

 

May 2017

 

9.21 (E7RG)

 

1.02 (E4OC)

 

1.19 (43A1)

 

1.254 (37A9)

 

1.10

(n/a)

 

2.20

(n/a)

 

1.2

(n/a)

 

0ACEE007

19-Mar-15

IC695CPE330- ABAK

IC695CPE330CA- ABAK

 

 

March 2017

 

9.10 (E7J9)

 

1.02 (E4OC)

 

1.19 (43A1)

 

1.254 (37A9)

 

1.10

(n/a)

 

2.20

(n/a)

 

1.2

(n/a)

 

0ACEE007

19-Mar-15

IC695CPE330- ABAJ IC695CPE330CA-

ABAJ

 

 

July 2016

 

8.95 (E6FJ)

 

1.02 (E4OC)

 

1.19 (43A1)

 

1.241 (20A4)

 

1.10

(n/a)

 

2.20

(n/a)

 

1.2

(n/a)

 

0ACEE007

19-Mar-15

IC695CPE330- ABAH

IC695CPE330CA- ABAH

 

 

May 2016

 

8.90 (E6AO)

 

1.02 (E4OC)

 

1.19 (43A1)

 

1.241 (20A4)

 

1.10

(n/a)

 

2.20

(n/a)

 

1.2

(n/a)

 

0ACEE007

19-Mar-15

IC695CPE330- AAAG IC695CPE330CA-

AAAG

 

 

Feb 2016

 

8.80 (E5RM)

 

1.02 (E4OC)

 

1.19 (43A1)

 

1.229 (38A8)

1.10

(n/a)

2.20

(n/a)

1.2

(n/a)

 

0ACEE007

19-Mar-15

IC695CPE330- AAAF

 

Dec 2015

8.75 (B5O1)

1.02 (E4OC)

1.19 (43A1)

1.229 (38A8)

1.10

(n/a)

2.20

(n/a)

1.2

(n/a)

0ACEE007

19-Mar-15

IC695CPE330- AAAE

 

Nov 2015

8.70 (E5KG)

1.02 (E4OC)

1.19 (43A1)

1.171 (16A14)

1.6

(n/a)

2.20

(n/a)

1.2

(n/a)

0ACEE007

19-Mar-15

IC695CPE330- AAAD

 

Aug 2015

8.60 (E55G)

1.02 (E4OC)

1.19 (43A1)

1.171 (16A14)

1.6

(n/a)

2.20

(n/a)

1.2

(n/a)

0ACEE007

19-Mar-15

IC695CPE330- AAAC

 

June 2015

8.55 (E4YL)

1.02 (E4OC)

1.19 (43A1)

1.171 (16A14)

1.6

(n/a)

2.20

(n/a)

1.2

(n/a)

0ACEE007

19-Mar-15

IC695CPE330- AAAB

 

May 2015

8.50 (E4V9)

1.02 (E4OC)

1.19 (43A1)

1.171 (16A14)

1.6

(n/a)

2.20

(n/a)

1.2

(n/a)

0ACEE007

19-Mar-15

IC695CPE330- AAAA

IC695CPK330

Mar 2015

8.45 (E4P6)

1.02 (E4OC)

1.19 (43A1)

1.110 (11A12)

1.5

(n/a)

2.19

(n/a)

1.2

(n/a)

0ACEE007

19-Mar-15

 

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.