GE / IP FANUC Series 90/30 In Stock

Call Now

1-800-360-6802

Mon-Fri 8AM-5PM EST

1-919-535-3180

IC695PBM300

Rated 4.6/5 Based on 12 ratings.

Rate your purchase of the IC695PBM300

IC693PWR324 IC695PBM300 In Stock! RX3i PROFIBUS Master Module (must be installed on RX3i PCI bus). IC695P IC695P IC695PBM300 In Stock! RX3i PROFIBUS Master Module (must be installed on RX3i PCI bus). IC695P IC695P

SKU 2177320  UPC 0914329153791

New Surplus

$1500

4 In Stock

3 Year warranty

*What is
New Surplus?

Reman

$825

1 In Stock

2 Year warranty

*What is
Remanufactured?

Repair

$642

Fast turnaround

1 Year warranty

1-800-360-6802

Order Today - Ships Today!


*US continental orders placed before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the IC695PBM300 -AA-BA-BB-BC-CCCALT

Product Description


The IC695PBM300 is a PROFIBUS Master module from the GE Fanuc RX3i Series. This module allows the RX3i CPU to send and receive data on a PROFIBUS-DP network.   See specifications for this unit on IC695PBM300's website page.

Technical Specifications


Module Type: PROFIBUS Master 
Number of Slots: 1 (single slot)
Backplane Support:   Universal
Protocol Support: up to 125 PROFIBUS-DP slaves 
Communication Ports:   RS-232
Internal Power: 440 mA @ 3.3 VDC

 

Technical Information

Specifications:

Environment

Storage temperature = -40C to 85C Operating temperature = 0C to 60C

Backplane Compatibility

RX3i PCI

Backplane Current Consumption

440 mA @ 3.3 Vdc

Data rates

Supports all standard data rates (9.6 kBit/s, 19.2 kBit/s, 93.75 kBit/s, 187.5 kBit/s, 500 kBit/s, 1.5

MBit/s, 3 MBit/s, 6 MBit/s and 12 MBit/s)

Status Information Available

Slave Status Bit Array Table Network Diagnostic Counters DP Master Diagnostic Counters Firmware Module Revision Slave Diagnostic Address

Data Sizes

The amount of data that can be configured on the PBM300 PROFIBUS network provides up to 3584 bytes input and 3584 bytes output.

For product standards and general specifications, refer to the PACSystems RX3i System Manual, GFK-2314.

 

Troubleshooting

Troubleshooting IC695PBM300

Troubleshooting information is available on IC695PBM300's website page; it also includes a datasheet user-manual and a wiring diagram.


Repair your IC695PBM300

PDF Supply can repair your IC695PBM300 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

Customer Questions and Answers


  • Question:  What is an IC695PBM300? Answer:  The IC695PBM300 is a PROFIBUS Master module from the GE Fanuc RX3i Series. 
  • Question:  What does IC695PBM300 do?   Answer:  The RX3i PROFIBUS Master module allows the RX3i CPU to send and receive data on a PROFIBUS-DP network.
  • Question:  What are some of the features of IC695PBM300?  Answer:
    • Supports up to 125 PROFIBUS-DP slaves
    • Supports up to 244 bytes of input data and 244 bytes of output data per slave
    • Supports up to 3,584 bytes of input data and 3,584 bytes of output data- total
    • Supports all standard data rates
    • Supports Sync and Freeze modes
    • Supports DP-V1 read, write, and alarm messages
    • PROFIBUS-compliant module and network status LEDs
  • Question:  What version of CPU firmware does this module require?  Answer:  IC695PBM300 requires an RX3i CPU with firmware version 2.9 or later.
  • Question:  Where must IC695PBM300 be located?  Answer:  This module must be located in a RX3i Universal Backplane.
  • Question:  For configuration, what does this module require?  Answer:  This module requires Machine Edition Version 5.0 SP2 Logic Developer-PLC or later for configuration.
  • Question:  What should I do if my IC695PBM300 is not working properly?  Answer:  Your IC695PBM300 may need repair.

For more information on the IC695PBM300 PROFIBUS Master Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.

Rel.

Ver.

Date

IPI

Upgrade Kit

New Features

Problems Resolved

CC

1.04

Jun-2010

GFK-2359D

44A753033-G01

N/A

N/A - Label change only. No change in functionality, performance or compatibility.

BC

1.04

May-2006

GFK-2359C

44A753033-G01

N/A

When multiple Lumberg devices (8in4out) are connected to the bus and power is removed from these devices, but the PBM300 remains powered, the inputs assigned to the Lumberg devices will toggle between 1 and 0.

Configuring slaves with a large amount of parameter data returns the correct error code when parameter data exceeds the available memory space.

BB

1.02

Apr-2005

GFK-2359B

44A753033-G01

The number of Message Segments used to hold mail messages has been doubled from 32 to 64.

When a Get Master Status CommReq is called on the first PLC scan, the CommReq no longer falsely returns a positive indication that the Profibus network has ý1 or More Slaves Not in IO Exchange Mode.ý

BA

1.00

Feb-2005

GFK-2359A

NA

UL Class I, Groups A, B, C & D, Div 2 Hazardous Locations

NA

AA

1.00

Dec-2004

GFK-2359

N/A

Initial Release of Product

Initial Release of Product

 

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.