World's Largest Warehouse of
GE 90-30, Genius, and RX7i

GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

1-919-535-3180

1-800-360-6802

Mon-Fri 8AM-5PM EST

IC698CRE030

Rated 4.7/5 Based on 15 ratings.

Rate your purchase of the IC698CRE030

IC698CRE030 600mHz CPU, Ethernet, Redundancy IC698C IC698CR IC698CRE PDFsupply also repairs GE IP FA

IC698CRE030 600mHz CPU, Ethernet, Redundancy IC698C IC698CR IC698CRE PDFsupply also repairs GE IP FA IC698CRE030 600mHz CPU, Ethernet, Redundancy IC698C IC698CR IC698CRE PDFsupply also repairs GE IP FA IC698CRE030

SKU 2177344  UPC 0692595701662

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.

MSRP $26219

"Best Value"

Surplus New

$19500

Save $6,719

1 In Stock

3 Year warranty

*What is Surplus New?

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the IC698CRE030 -AA-AB-BB-CB-CC-DC-DD-DE-EE-EF-EG-EH-FK-FL-FM-GM-HN-Programming Software

Product Description



The IC698CRE030 is a PACSystems RX7i Central Processing Unit. The RX7i CPU is programmed and configured by programming software to perform control of machines, processes, and systems in real time. It is able to communicate with I/O and smart option modules over a rack-mounted backplane using the VME64 Standard format. An embedded Ethernet port or serial port enables the CPU to communicate with the programmer and HMI devices. This particular model utilizes a 600MHz Pentium-M microprocessor (64 MB both user memory and flash).


Highlights of this unit include HSB or hot standby redundancy, battery-backed user memory and non-volatile flash memory allowing for program, configuration, register data, and symbolic variable storage. It is bulk memory accessible via reference table %W. It features programming in Ladder Diagram, C, Structured Text, and Function Block Diagram. Auto-located Symbolic Variables conveniently use unlimited memory. A number of modules are supported, including 90-70 Series discrete and analog I/O as well as VME modules. Please see the installation module for a list of other supported modules.


The IC698CRE030 CPU allows both data monitoring across the web and a maximum of 16 web server/FTP connections. Block size may not exceed 128KB, but 512 program blocks are supported. Furthermore, the unit is equipped with word referencing, a battery-backed calendar clock, serial port enabled firmware upgrades, and three isolated serial ports.

EGD data exchange, TCP/IP communication services, station management, diagnostic tools, and time synchronization to the timeserver are all made possible by an embedded Ethernet interface. Additionally, a redundant IP (configurable by the user) facilitates EGD exchange production.

 

Power requirements for the IC698CRE030 are as follows: +5 VDC: 3.2 Amps nominal, +12 VDC: 0.003 Amps nominal, and -12 VDC: 0.003 Amps nominal. 

Technical Specifications


Processing Speed: 600 MHz
CPU Memory: 64 Mbytes
Floating Point: Yes
Serial Ports: 3
Serial Protocols: Modbus RTU Slave, SNP, Serial I/O
Embedded Comms:  RS-232, RS-486. Ethernet interface

 

Technical Information

 

Battery: Memory retention

For battery selection, installation and estimated life, refer to the

PACSystems Controller Battery and Energy Pack Manual, GFK-2741.

Program storage

Up to 64 Mbytes of battery-backed RAM

64 Mbytes of non-volatile flash user memory

Power requirements: CRE030

 

CRE040

+5 VDC: 3.2 Amps nominal

+12 VDC: 0.003 Amps nominal

-12 VDC: 0.003 Amps nominal

+5 VDC: 6.8 Amps nominal

+12 VDC: 0.003 Amps nominal

-12 VDC: 0.003 Amps nominal

Operating temperature: CRE030

 

CRE040

0 to 50°C (32°F to 122°F)

0 to 60°C (32°F to 140°F) with fan tray

0 to 60°C (32°F to 140°F), fan tray required

Boolean execution speed, typical: CRE030

CRE040

0.069ms per 1000 Boolean contacts/coils

0.024ms per 1000 Boolean contacts/coils

Time of Day Clock accuracy

Maximum drift of ±2 seconds per day

Elapsed Time Clock (internal timing) accuracy

±0.01% maximum

Embedded communications

RS-232, RS-485, Ethernet interface

Serial Protocols supported

Modbus RTU Slave, SNP, Serial I/O

Ethernet Ports

Embedded auto-sensing 10/100 Mbps half/full duplex Ethernet interface

VME Compatibility

System designed to support the VME64 standard ANSI/VITA 1

Program blocks

Up to 512 program blocks. Maximum size for a block is 128KB.

Memory

(For a detailed listing of memory areas, refer to the CPU Reference Manual, GFK-2222.)

%I and %Q: 32Kbits for discrete

%AI and %AQ: configurable up to 32Kwords

%W: configurable up to the maximum available user RAM Managed memory (Symbolic and I/O variables combined): configurable up to 10 Mbytes

Ethernet Interface Specifications

 

Web-based data monitoring

Up to 16 web server and FTP connections (combined)

Ethernet data rate

10Mb/sec and 100Mb/sec

Physical interface

10BaseT RJ45

WinLoader support

Yes

Number of EGD configuration-based pages

255

Time synchronization

SNTP

Selective consumption of EGD

Yes

Load EGD configuration from RX7i to programmer

Yes

Remote Station Manager over UDP

Yes

Local Station Manager (RS-232)

Dedicated RS-232 port

Configurable Advanced User Parameters

Yes

Troubleshooting

Troubleshooting IC698CRE030

Troubleshooting information is available on IC698CRE030's website page; it also includes a datasheet user-manual and a wiring diagram.

 

Repair your IC698CPE030

PDF Supply can repair your IC698CRE030 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

 

Customer Questions and Answers


  • Question:  What is an IC698CRE030?  Answer:  The IC698CRE030 is a 600 MHz Central Processing Unit with Hot Stand-by Redundancy from the GE Fanuc RX7i Series with an Intel Pentium-M microprocessor. 
  • Question:  What does Hot Standby CPU Redundancy in an IC698CRE030 do?  Answer:   Hot Standy CPU Redundancy allows a critical application or process to continue operating if a failure occurs in any single component. 
  • Question:  How many CPUs are required?  Answer:  A Hot Standy system uses two CPUs; and active unit that actively controls the process, and a backuo unit that is synchronized with the active unit and can take over the process if it becomes necessary.
  • Question:  How does IC698CRE030 communicate with I/O and Intelligent Option modules?  Answer:  The CPU communicates over a rack-mounted backplane using the VME64 Standard format.
  • Question:  What else is required wtih the IC698CRE030 to accomplish redundancy?  Answer:  A Redundacy Memory Xchange module (IC698RMX016) configured as a redundancy link in each unit. 
  • Question: How can I avoid RAM memory loss?  Answer:  Routine maintenance procedures should include scheduled replacement of the CPU's IC698ACC701 lithium battery pack.  The battery maintains program and data memory and operates the calendar clock when the power is removed.
  • Question:  If I don't have any light on or the CPU is not functioning correctly - What does that mean?  Answer:  It means there is something wrong with your processor and it will need repair or maybe even replacement. 

For more information on the IC698CRE030 Central Processing Unit of the GE Fanuc RX7i Series, please see the Datasheet User-Manual.

 

Catalog Number Date CPU Ethernet Firmware Version
    Firmware Version  
IC698CRE030-HN/CRE040-HN May. 2013 6.75 6.2
IC698CRE030-GM/CRE040-GM May. 2012 6.75 6.13
IC698CRE030-FM/CRE040-FM Mar. 2012 6.75 6.13
IC698CRE030-FL/CRE040-FL Feb. 2012 6.75 6.12
IC698CRE030-FK/CRE040-FK Nov. 2011 6.75 6.1
IC698CRE030-FJ/CRE040-FJ Jul. 2011 6.71 6.1
IC698CRE030-FH/CRE040-FH Nov. 2010 6.01 6
IC698CRE030-EH/CRE040-EH Mar. 2010 6.01 6
IC698CRE030-EG/CRE040-EG Sep. 2009 6 6
IC698CRE030-EF/CRE040-EF Dec. 2008 5.5 5.51
IC698CRE030-EE/CRE040-EE Oct. 2008 5.5 5.5
IC698CRE030-DE/CRE040-DE May. 2008 5.5 5.5
IC698CRE030-DD/CRE040-DD Dec. 2007 5 5.01
IC698CRE030-DC/CRE040-DC Oct. 2007 5 5
IC698CRE030-CC/CRE040-CC Aug. 2007 5 5
IC698CRE030-CB/CRE040-CB Jul. 2007 4.02 4
IC698CRE030-BB/CRE040-BB Jul. 2007 4.02 4
IC698CRE030-AB/CRE040-AB Dec. 2006 4.02 4
IC698CRE030-AA/CRE040-AA Oct. 2006 4.01 4
IC698CRE020-DD Apr. 2005 2.04 3

 

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

Common related search terms: BatteryConfigurationDatasheetManualPDFPLCPriceRepairSpecificationTroubleshootUser-ManualWiring

All online orders placed before 4:30 PM EST “SHIPS SAME DAY FREE!" World’s largest warehouse of Factory Sealed GE 90-30 PLC, GENIUS I/O and RX7i PACSystem.highlight_off

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.