World's Largest Warehouse of
GE 90-30, Genius, and RX7i

GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

1-919-535-3180

1-800-360-6802

Mon-Fri 8AM-5PM EST

IC693CPU323

Rated 4.7/5 Based on 29 ratings.

Rate your purchase of the IC693CPU323

Image of IC693CPU323

Image of IC693CPU323 IC693CPU323 In Stock! 10-Slot Rack With Turbo CPU in base IC693C IC693CP IC693CPU PDFsupply also rep IC693CPU323

SKU 2178148  UPC 0895862187101

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.

MSRP $2520


New

  ON SALE ! 
$1995

Save $525

8 In Stock

2 Year warranty

*Need a Specific Revision?

"Like New Condition"

Remanufactured

$395

Save $2,125

3 In Stock

2 Year warranty

*What is Remanufactured?

"Avg. Repair - 2 Days"

Repair Service

$288

Save $2,232

Fast or Free!

2 Year warranty

*What is Fast Repair?

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the IC693CPU323 -Programming Software-SoftwareABCCADEGHKLLTMNPQRRRSTUVWX

Product Description


The GE Fanuc IC693CPU323 is a 10-Slot Base Turbo CPU. This unit has 12 Kb of User Program Memory. The Series 90-30 PLC family comprises controllers and I/O systems as well as speciality modules. These are all designed specifically to give the user a more versatile and extensive control system over their industrial applications and processes. Due to the wide range of available modules, it is easy to introduce automated processes to your business. Among the range are 14 powerful CPU units. The IC693CPU323 is a standard CPU, best suited to entry-level applications that have low I/O counts. As the CPU is embedded in the backplane, all I/O slots are available for use. Advanced modules such as motion control and Ethernet can be used with this CPU.

 

Technical Specifications


Processor Speed : 10 MHz
I/O Points : 320
Register Memory : 2KBytes
Floating Point Math:    No
16 BIT system Yes
Processor: 80188

 

Technical Information

 

 

CPU Type

10-slot baseplate with embedded CPU

Total Baseplates per System

1

Load Required from Power Supply

430 milliamps from +5 VDC supply

Processor Speed

10 MegaHertz

Processor Type

80188

Operating Temperature

0 to 60 degrees C (32 to 140 degrees F) ambient

Typical Scan Rate

0.6 milliseconds per 1K of logic (boolean contacts)

User Program Memory (maximum)

12K Bytes (6K bytes prior to release 7)

Discrete Input Points - %I

Discrete Output Points - %Q

320 (maximum - combined inputs + outputs)

320 (maximum - combined outputs + inputs)

Discrete Global Memory - %G

1280 bits

Internal Coils - %M

1024 bits

Output (Temporary) Coils - %T

256 bits

System Status References - %S

128 bits (%S, %SA, %SB, %SC - 32 bits each)

Register Memory - %R

1024 words

Analog Inputs - %AI

64 words

Analog Outputs - %AQ

32 words

System Registers (for reference table viewing only; cannot be referenced in user logic

program)

16 words (%SR)

Timers/Counters

340

Shift Registers

yes

Built-in Ports

1 (uses connector on PLC power supply). Supports SNP slave and SNP-X slave protocols.

Communications

LAN - Supports multidrop. Also supports Ethernet, FIP, Profibus, GBC, GCM, GCM+ option modules.

Override

no

Battery Backed Clock

no

Interrupts

no

Type of Memory Storage

RAM and optional EPROM or EEPROM

PCM/CCM Compatibility

no

 

Troubleshooting

Troubleshooting IC693CPU323

Troubleshooting information is available on IC693CPU323's website page; it also includes a datasheet user-manual and a wiring diagram.

 

Repair your IC693CPU323

PDF Supply can repair your IC693CPU323 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty. 

 

Customer Questions and Answers


  • Question:  What is an IC693CPU323?  Answer:  The IC693CPU323 is a 10 slot rack with an embedded Turbo Central Processing Unit (from the GE Fanuc Series 90-30). This unit is the "brains" of the PLC and is where most of the calculations take place. 
  • Question:  What's the first thing you should do when testing your IC693CPU323?  Answer:  When you power the IC693CPU323 up, you should be checking for an OK light.
  • Question:  What if I do not have an OK light after I have powered it up?  Answer:  If you don't have an OK light, then you won't be able to follow through with the test. The lack of an OK light indicates, right from the start, there is something wrong with your IC693CPU323.
  • Question:  What is this initial test showing?  Answer:  You're basically turning on the configuration and logic in this processor in order to set it to run mode. You want to see that this is a good working processor.
  • Question:  With what software should I test my IC693CPU323?  Answer:  You can test your IC693CPU323 with Proficy Machine Edition. 
  • Question:  What will I need to test my IC693CPU323?  Answer:  All you will need is your IC693CPU323 and a power supply.
  • Question:  If I think there is a problem with my processor, what should I do?  Answer:  You should, first, make sure the RUN light comes on and then let the processor run overnight (or even 2-3 days). This is to check that it's able to sustain itself in run mode. (You want to make sure it doesn't fail or fall out of run mode for any reason.) If it does fail or fall out of run mode, then you can try reading the faults or errors through the Proficy Machine Edition software. It may give you enough information to help you fix the problem. 
  • Question:  If I can't figure out how to fix my IC693CPU323, what is my next step?  Answer:  PDF Supply can repair your IC693CPU323 for you. 

For more information on the IC693CPU323 Central Processing Unit of the GE 90-30 Series, please see the Datasheet Manual. 

 

Rel.

Ver.

Date

IPI

Upgrade Kit

New Features

Problems Resolved

V

8.40

May-01

GFK-0702ac

 

  • Battery now ships with CPU and not with the Power Supply

 

U

8.40

Jan-00

GFK-0702aa

44A735538-G12

  • Ignore Fatal Fault Feature

 

T

8.21

Oct-98

GFK-0702z

 

  • DSM312 Support Added
  • FBC Editing with HHP
  • Storing Foreign Module Configuration to Slot 1
  • End Function Block
  • SVC REQ 7

S

8.20

Mar-98

GFK-0702y

 

  • Break-free SNP (improves modem compatibility)
  • HHP Write to Flash or EEPROM with IC641 Programmer Connected

R

8.00

Oct-97

GFK-0702x

 

 

 

P

8.00

Jun-97

GFK-0702v

 

  • Support for Larger Configuration File
  • Model Number Checks Removed

 

N

7.00

Nov-96

GFK-0702t

 

  • User memory increased from 6K bytes to 12K bytes
  • ALT-S in Stop Mode
  • HHP Overrides
  • HHP Coil Use
  • HHP Subroutines

M

6.61

Jun-96

GFK-0702s

 

  • Bumpless Run Mode Store
  • PID Function Block Enhancement
  • Write Datagram
  • Zeroing Input Data of a Failed Module
  • Storing Folder to EEPROM

L

6.51

Mar-96

GFK-0702r

 

  • Multiple Backplane and SNP Sessions
  • Storing a Maximum Size Program Block
  • Adding Smart Modules
  • Reconfiguring Smart I/O Modules
  • Multiple Channel Connections
  • Update Utility Error Messages
  • Configuring Smart Modules with the HHP
  • PLC Software Fault
  • SFC Reset
  • SNPX Interrupted Message

K

5.03

Jul-95

GFK-0702q

 

 

  • SNPX Power-Cycle Recovery

J

5.01

Feb-95

GFK-0702n

 

 

  • DINT Function Block with Constant Parameter
  • Clearing I/O Fault Table with GBC Present but not Configured

H

5.00

Dec-94

GFK-0702m

 

  • BEM331 Genius Bus Controller
  • Sequential Function Chart Programming
  • Automatic Baud Rate Detection
  • Katakana HHP Display
  • PLC State After Error During Device Read
  • SNP Conformance
  • SNPX Access to System References
  • Noise Immunity
  • Store Fault Registration Delay
  • Brown-Out During SNPX Session
  • OIT Response
  • Day of the Week
  • Modem Turnaround Time

G

4.50

Nov-94

GFK-0702l

 

  • CE approval

 

F

4.50

Aug-94

GFK-0702j

 

  • Communication Windows

 

E

4.40

Feb-94

GFK-0702g

 

  • UL Class I DIV 2 and C-UL approval

 

D

4.40

 

GFK-0702g

 

  • OffDelay (OFDTR) Function 14
  • Active and Constant Sweep Modes
  • SVCREQ #26: Interrogate I/O
  • SVCREQ #23: Read Master Checksum
  • Masked Compare Word (MSKCMPW) Function 143
  • Masked Compare Dword (MSCCMPD) Function 144
  • Number of Enhanced GCMs Allowed
  • SNPX Protocol
  • I/O Link Master Module
  • Window Modes
  • Run-Mode Store
  • Range Function Block
  • Retentiveness of %G References

 

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

Common related search terms: BatteryBuyConfigurationDatasheetDimensionFirmwareManualPriceRepairSpecificationTroubleshootWiring

All online orders placed before 4:30 PM EST “SHIPS SAME DAY FREE!" World’s largest warehouse of Factory Sealed GE 90-30 PLC, GENIUS I/O and RX7i PACSystem.highlight_off

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.