IC693PBM200

Rated 4.6/5 Based on 17 ratings.

Rate your purchase of the IC693PBM200

IC693PWR324 IC693PBM200 Siemens Profibus DP Master Module IC693P IC693PB IC693PBM PDFsupply also repairs GE IP F IC693PBM200 Siemens Profibus DP Master Module IC693P IC693PB IC693PBM PDFsupply also repairs GE IP F IC693PBM200

SKU 2172453  UPC 0223815382455

MSRP $4253

New

$2995

Save $1,258

7 In Stock

2 Year warranty

*Need a Specific Revision?

New Surplus

$2250

Save $2,003

2 In Stock

3 Year warranty

*What is New Surplus?

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the IC693PBM200 -AA-BB-BC-CC-DD-DE-EE-FECALTRR

Product Description


The GE Fanuc IC693PBM200 is a Master module for the PROFIBUS DP networks. Users can mount the Master module in any Series 90-30 baseplate slot except slot 1 of a modular CPU baseplate.  The Master module allows an IC693 PLC to send and receive I/O data from a PROFIBUS DP network. Among the features are Sync and Freeze modes and LED indicators for both the PROFIBUS-compliant COM and SYS. Users can update the firmware on the master module using the service port.

The Master module supports all standard data rates as well as up to 125 DP slaves. It also supports 244 bytes of input and output for each slave. Configuring the Master module requires specific software. It requires ME Logic Developer PLC programming software and it must be version 3.0 or later. When a user is migrating from the HE693PBM101 PROFIBUS Master Module, they should consider a few issues. Firstly, the slave status area on the IC693PBM200 is 128 points by default – twice the size of the 64 point HE693PBM101. You may need to reduce the size of the slave status area according to the usage of the previous module.

Unlike the HE693PBM101, the IC693PBM200 enters Clear Mode whenever the PLC is not scanning its I/O. Furthermore, the slave status bits are arranged differently in these two modules. The HE693PBM101 arranges bits by the order of appearance in the configuration. On the other hand, the IC693PBM200 arranges bits in order of bus address.  There is a limit to the amount of data that may be exchanged between a CPU and module. For the IC693PBM200, that limit is 3,972 bytes of input data. Input data is the data going from the Master module to the CPU. The limit going in the opposite direction is output data. It has the same limit of 3,972 bytes. 

Technical Information

Specifications

 

Catalog Number

IC693PBM200

Description

Series 90-30 Master module for PROFIBUS DP networks

Configuration Software Requirement

Proficy™ Machine Edition Logic Developer version 2.6 or later

CPU Version Requirement

CPU firmware version 8.00 or later

Mounting Location

Any Series 90-30 baseplate (CPU, expansion, or remote) slot except slot 1 of a modular CPU baseplate

Environment

Storage temperature = -40ï‚°C to 85ï‚°C

Operating temperature = 0ï‚°C to 60ï‚°C

Backplane Current Consumption

450mA @ 5VDC (typical)

Data rates

Supports all standard data rates (9.6K, 19.2K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M and 12M Baud)

Status Information Available

Slave Status Bit Array

Slave Diagnostics/Firmware ID array Network diagnostic counters

DP master diagnostic counters

Firmware module revision Slave Diagnostic Address

 

Troubleshooting

Troubleshooting IC693PBM200

Troubleshooting information is available on IC693PBM200's website page; it also includes a datasheet user-manual and a wiring diagram.  

 

Repair your IC693PBM200

PDF Supply can repair your IC693PBM200 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

IC693PBM200 To Work as Profibus PA Master

Description

PROFIBUS specifications reference three different protocols to cover a range of industrial requirements:

  • PROFIBUS-DP High speed data communication. DP stands for Decentralized Periphery. In practice, the majority of slave applications are DP applications.
  • PROFIBUS-FMS Object oriented general-purpose data communication. FMS stands for FieldBus Message Specification. FMS protocol devices may exchange data on the same bus used for DP devices.
  • PROFIBUS-PA Meets requirements for intrinsic safety and non-intrinsic safety areas and includes bus powered field devices.

Resolution

IC693PBM200 is Profibus Master module in GE S9030 Series PLC, but it only can be Profibus DP mater, can't be Profibus PA Master.

Pepperl Fuchs (http://www.pepperl-fuchs.com/) provided a DP-PA coupler, that can convert IC693PBM200 from DP Master to PA Master.

 

Adding Versapoint Modules in a Profibus Network by Using Machine Edition

Description

To add a versapoint profibus in a 9030 or 9070 PLC system refer to the following:

Resolution

  1. Need to have one profibus master configured on 9030 or 9070 rack.  Configure the Station ID, network settings for this master module, i.e. using IC693PBM200 as master on 9030 rack.
  2. Add a versapoint profibus slave, If you are adding a profibus slave which is not on the list, you need to load GSD file for this slave by Click on ?Have Disk..?. and Configure the station ID , make sure the network setting should be exactly same as master module.
  3. After the profibus NIU configuration, configure the I/O modules in this slave configuration

And all the data transferred from slave will map to the master PLC system memory configured.

 

Customer Questions and Answers


  • Question:  What is an IC693PBM200?  Answer:  The IC693PBM200 is a PROFIBUS Master module. The Master module allows the host (Series 90-30) CPU to send and receive I/O data from a PROFIBUS-DP network. 
  • Question:  What features does IC693PBM200 provide?  Answer:
    • It supports all standard data rates.
    • It supports a maximum of 125 DP slaves.
    • It supports 244 bytes of input and 244 bytes of output for each slave.
    • It supports Sync and Freeze modes.
    • It is a PROFIBUS-compliant module and has Network Status LEDs.
    • It provides an RS-232 serial port (the Service port) for upgrading the firmware.
  • Question:  What configuration software is required for IC693PBM200?  Answer:  Proficy Machine Edition Logic Developer version 2.6 or later
  • Question:  What is the CPU Version requirement?  Answer:  CPU firmware version 8.00 or later
  • Question:  Where should IC693PBM200 be mounted?  Answer:  IC693PBM200 can be mounted in any Series 90-30 baseplate (CPU, Expansion, or Remote) slot except slot 1 of a modular CPU baseplate.
  • Question:  What is the storage temperature for IC693PBM200?  Answer:  -40 degrees C to 85 degrees C
  • Question:  What is the operating temperature for IC693PBM200?  Answer:  0 degrees C to 60 degrees C
  • Question:  What should I do if my IC693PBM200 is not working properly?  Answer:  Your product may need repair

For more information on the IC693PBM200 PROFIBUS Master Module of the GE 90-30 Series, please see the Datasheet Manual. 

 

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

Common related search terms: BuyConfigurationDatasheetManualPriceRepairSpecificationTroubleshootWiring

All online orders placed before 4:30 PM EST “SHIPS SAME DAY FREE! World’s largest warehouse of Factory Sealed GE 90-30, Genius and Rx7i PLC.highlight_off

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.