World's Largest Warehouse of
GE 90-30, Genius, and RX7i

GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

1-919-535-3180

1-800-360-6802

Mon-Fri 8AM-5PM EST

HE693ADC410

Rated 4.4/5 Based on 10 ratings.

Rate your purchase of the HE693ADC410

Horner Electric | Horner Electric | HE693ADC410 | Image

Horner Electric | Horner Electric | HE693ADC410 | Image Horner Electric | Horner Electric | HE693ADC410 | Image

SKU 2172029  UPC 0819618876347

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.

MSRP $3995

"Avg. Repair - 2 Days"

Repair Service

$995

Save $3,000

Fast or Free!

2 Year warranty

*What is Fast Repair?

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the HE693ADC410 ABCDEFGHIJKLMNOPQRSTUVWXYZ

The Horner APG +/-10V Isolated Analog Input Modules provide four analog input channels with 14-bits of resolution. The isolation levels for this unit are channel-to-channel and channel-to-ground. This module converts voltage input signals to digital values (-32,000 to +32,000), which are placed directly into the %AI table of the PLC CPU. Each of the four channels of the module has a programmable setpoint (the level of which is set in the PLC program via four %AQ output registers). When the analog input value reaches or exceeds the setpoint, a corresponding digital input %I is energized. The first four %Is represent the four input channel setpoint alarms respectively. 

Technical Specifications


Steady-State Power Consumption ADC405: .4W / 80mA @ 5V, 2.16W / 90mA @ 24V ADC410: .7W / 140mA @ 5V, 1.2W / 50mA @ 24V
Surge Current at Power-Up ADC405: 120mA @ 5V 150mA @ 24V ADC410: 200mA @ 5V 100mA @ 24V
Number of Channels 4
I/O Required 4 %AI, 4 %AQ, 16 %I
A/D Type, Resolution Integrating, 18 bits
Useable Resolution 13 bits plus sign
Module Update Rate 45 channels/S
Digital Filtering 1-128 samples / update
Analog Filtering 1KHz, 3 pole Bessel
Maximum Error .05% full scale
Input Impedance 1 Megohm
Maximum Over-Voltage +/- 15VDC
Channel to Channel (ADC410) 1500VAC (RMS), +/- 2000VDC
Common Mode Range (ADC410) 1500VAC (RMS), +/- 2000VDC
Channel to Channel (ADC405) 500VAC (RMS), +/-700VDC
Common Mode Range (ADC405) 500VAC (RMS), +/-700VDC
Common Mode Rejection >100dB
Relative Humidity 5% to 95%, non-condensing
Operating Temperature 0 to 60°C (32 to 140°F)

Technical Information

Steady-State Power Consumption ADC405: .4W / 80mA @ 5V, 2.16W / 90mA @ 24V ADC410: .7W / 140mA @ 5V, 1.2W / 50mA @ 24V
Surge Current at Power-Up ADC405: 120mA @ 5V 150mA @ 24V ADC410: 200mA @ 5V 100mA @ 24V
Number of Channels 4
I/O Required 4 %AI, 4 %AQ, 16 %I
Input Range +/- 10V
A/D Type, Resolution Integrating, 18 bits
Useable Resolution 13 bits plus sign
Module Update Rate 45 channels/S
Digital Filtering 1-128 samples / update
Analog Filtering 1KHz, 3 pole Bessel
Maximum Error .05% full scale
Input Impedance 1 Megohm
Maximum Over-Voltage +/- 15VDC
Channel to Channel (ADC410) 1500VAC (RMS), +/- 2000VDC
Common Mode Range (ADC410) 1500VAC (RMS), +/- 2000VDC
Channel to Channel (ADC405) 500VAC (RMS), +/-700VDC
Common Mode Range (ADC405) 500VAC (RMS), +/-700VDC
Common Mode Rejection >100dB
Relative Humidity 5% to 95%, non-condensing
Operating Temperature 0 to 60°C (32 to 140°F)
  • Question: What is a HE693ADC410? Answer: The HE693ADC410 provides four input channels with 14 bits of resolution.
  • Question: What is the main power supply for the HE693ADC410? Answer: The main power source for this unit comes from ADC405: .4W / 80mA @ 5V, 2.16W / 90mA @ 24V or ADC410: .7W / 140mA @ 5V, 1.2W / 50mA @ 24V which is supplied by the PLC power supply. 
  • Question: How can I minimize capacitive loading and noise? Answer: Shielded, twisted-pair extension wiring offers the best noise immunity. 
  • Question: Where should the shields be connected to? Answer: Wiring needs to be routed in its own conduit. If shielded wiring is used, a good earth ground must be used at one end only.
  • Question: Can I change the number of channels or the voltage on this device? Answer: Yes, you can. This is a 4 channel unit.
  • Question: What is a good way to test the HE693ADC410? Answer: The best method to test this unit is to use a +/-10Vdc power source to probe each channel for consistency and stability. 
  • Question: How to tell if your HE693ADC410 is faulty. Answer: Reference the response to each channel. Check for consistency and stability in the I/O tables. 

 

All online orders placed before 4:30 PM EST “SHIPS SAME DAY FREE!" World’s largest warehouse of Factory Sealed GE 90-30 PLC, GENIUS I/O and RX7i PACSystem.highlight_off

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.