HE693STG883

Rated 4.4/5 Based on 8 ratings.

Rate your purchase of the HE693STG883

Horner Electric | Horner Electric | HE693STG883 | Image

Horner Electric | Horner Electric | HE693STG883 | Image Horner Electric | Horner Electric | HE693STG883 - Wiring Diagram Image

SKU 2174467  UPC 0353997786069

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.

MSRP $3995

"Avg. Repair - 2 Days"

Repair Service

$795

Save $3,200

Fast or Free!

2 Year warranty

*What is Fast Repair?

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the HE693STG883 ABCDEFGHIJKLMNOPQRSTUVWXYZ

The HE693STG883 connects to a PLC to allow bridged strain gages to connect directly to the module without external signal processing (transducers, transmitters, etc). All analog and digital processing of the signal is performed on the module, and precision millivolt values are written to the series 90-30 %AI input table with 16-bit resolution. The input range of this module is +/-20mV, +/-25mV, or +/-30mV which is configurable through Logicmaster on a channel-by-channel basis. This provides a resolution of approximately0.6uV, 0.8uV, or 0.9uV, respectively. Also, individual channels can be turned off, so that unused channels do not increase module response time. Another ability of this module is to monitor the load cell excitation voltage and compensate for variations in this signal. Excitation voltage output is not supplied by the module. The HE693STG883 also features a setpoint for each channel, set with %AQ values and enunciated with %I inputs. Outputs (%Q) allow the ladder logic to trigger the module to perform a ZERO, TARE, or CLEAR function, critical for weighing applications.

Technical Specifications


Power Consumption Inrush: 150mA@5VDC 80mA@24V Relay Steady State: 60mA@5VDC 30mA@24V Relay
Number of Channels 8
I/O Required 8-%AI, 16-%I,8-%AQ,16%Q
Strain Gages Supported Bridged (Load Cells)
Input Range +/-20mV, +/-25mV, +/-30mV
Resolution .6uV, .8uV, .9uV, respecfully
Excitation Monitoring 10 VDC
Input Impedence >1000 Mohms
Accuracy .03%
Max Normal Voltage Input 100mV/td>
Maximum Safe Voltage +/- 35VDC or AC
A/D Conversion Type Integrating
A/D Conversion Time 35 channels per second
Operating Temperature 0 to 60°C (32 to 140°F)
Relative Humidity 5% to 95% non-condensing

Technical Information

Power Consumption Inrush: 150mA@5VDC 80mA@24V Relay Steady State: 60mA@5VDC 30mA@24V Relay
Number of Channels 8
I/O Required 8-%AI, 16-%I,8-%AQ,16%Q
Strain Gages Supported Bridged (Load Cells)
Input Range +/-20mV, +/-25mV, +/-30mV
Resolution .6uV, .8uV, .9uV, respecfully
Excitation Monitoring 10 VDC
Input Impedence >1000 Mohms
Accuracy .03%
Max Normal Voltage Input 100mV/td>
Maximum Safe Voltage +/- 35VDC or AC
A/D Conversion Type Integrating
A/D Conversion Time 35 channels per second
Operating Temperature 0 to 60°C (32 to 140°F)
Relative Humidity 5% to 95% non-condensing
  • Question: What is a HE693STG883? Answer: The HE693STG883 connects to a PLC to allow bridged strain gages to connect directly to the module without external signal processing (transducers, transmitters, etc). All analog and digital processing of the signal is performed on the module, and precision millivolt values are written to the series 90-30 %AI input table with 16-bit resolution.
  • Question: What is the main power supply for the HE693STG883? Answer:  The HE693STG883 uses 150mA@5VDC / 80mA @ 24V relay for inrush and 60 mA@5VDC / 30mA @ 24V relay for steady state.
  • Question: How can I minimize capacitive loading and noise? Answer: Shielded, twisted-pair extension wiring offers the best noise immunity. 
  • Question: Where should the shields be connected to? Answer: Wiring needs to be routed in its own conduit. If shields are connected at the module end, terminals 19 & 20 may be used as the shield ground.
  • Question: Can I change the number of channels or the voltage on this device? Answer: Yes, you can. Individual channels can be turned off so that unused channels do not increase module response time.
  • Question: What is a good way to test the HE693STG883? Answer: A good method of testing the HE693STG883 is to probe each channel with a strain gage and look for consistency and stability.
  • Question: How to tell if your HE693STG883 is faulty. Answer: Reference the response to each channel. 
All online orders placed before 4:30 PM EST “SHIPS SAME DAY FREE!" World’s largest warehouse of Factory Sealed GE 90-30 PLC, GENIUS I/O and RX7i PACSystem.highlight_off

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.