HE697THM160

Rated 4.8/5 Based on 7 ratings.

Rate your purchase of the HE697THM160

Image of HE697THM160

Image of HE697THM160 Image of HE697THM160

SKU 2177124  UPC 0242318390828

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.

MSRP $3995

"Like New Condition"

Remanufactured

$1950

Save $2,045

1 In Stock

2 Year warranty

*What is Remanufactured?

"Avg. Repair - 2 Days"

Repair Service

$1450

Save $2,545

Fast or Free!

2 Year warranty

*What is Fast Repair?

Order Today - Ships Today!

*US continental orders placed Monday-Friday before 4:30pm EST!

Lowest Price Guarantee

Other Available Revisions for the HE697THM160 ABCDEFGHIJKLMNOPQRSTUVWXYZ

The HE697THM160 offers 16 channels of thermocouple input with 0.1°C resolution. Ten thermocouple kinds are currently supported; J, K, N, T, E, R, S, B, C, and JX (extended J). Thermocouple type is optional on a channel-by-channel basis. The module allows the direct connection of thermocouple sensors, without the need for external signal conditioners and standard analog input modules. The thermocouple voltage is changed to a digital value, cold junction compensated, and the appropriate temperature value is reported directly to %AI registers in 0.1° or 0.5° increments. The temperature value may be reported in °C or °F increments. Various configuration parameters, as well as high and low setpoints for each channel, are available using %AQ output registers. Recommended wire size is 24 AWG. THM160 requires a power supply to provide ± 12V and 5V to the backplane.

Technical Specifications


Power Requirements

Number of Channels 16
Types Supported J, K, N, T, E, R, S, B, C, JX
Cold Junction Comp. Internal (AD592) External (AD592) Future Option
Resolution 0.1°C or 0.1°F
Accuracy +/-0.5°C typical (J, K, N, T)
Operating Temperature 0 to 60°C (32 to 140°F)
Relative Humidity 5% to 95% non-cond.
Input Impedance >20Mohms
Maximum Safe Overload +/-35V (from floating common)
Common Mode Range +/-11 V (from floating common)
Common Mode Rejection >100dB
A/D Conversion Type 16-bit, Successive Approx.
Channel Scan Rate 960 channels/second
Isolation 500VDC Bus Isolation

 

Technical Information

Number of Channels 16
Types Supported J, K, N, T, E, R, S, B, C, JX
Cold Junction Comp. Internal (AD592) External (AD592) Future Option
Resolution 0.1°C or 0.1°F
Accuracy +/-0.5°C typical (J, K, N, T)
Operating Temperature 0 to 60°C (32 to 140°F)
Relative Humidity 5% to 95% non-cond.
Input Impedance >20Mohms
Maximum Safe Overload +/-35V (from floating common)
Common Mode Range +/-11 V (from floating common)
Common Mode Rejection >100dB
A/D Conversion Type 16-bit, Successive Approx.
Channel Scan Rate 960 channels/second
Isolation 500VDC Bus Isolation
  • Question: What is a HE697THM160? Answer: The HE697THM160 offers 16 channels of thermocouple input with 0.1°C resolution. Ten thermocouple kinds are currently supported; J, K, N, T, E, R, S, B, C, and JX (extended J). Thermocouple type is optional on a channel-by-channel basis. The module allows the direct connection of thermocouple sensors, without the need for external signal conditioners and standard analog input modules.
  • Question: How many channels does the HE697THM160 have? Answer: The HE697THM160 has 16 channels.
  • Question: What equipment is needed for the HE697THM160? Answer: Extension wire of the proper Thermocouple type must be used. Unusedthermocouple inputs should be shorted together to avoid channel to channel cross-talk. Recommended wire size for the terminal strip is 24 AWG.
  • Question: What is the best method to reduce noise on the HE697THM160? Answer: Shielded, twisted-pair extension wiring offers the best noise immunity. 
  • Question: Does the HE697THM160 need grounding? Answer: If shielded wiring is used, a good earth ground connection is critical.

 

All online orders placed before 4:30 PM EST “SHIPS SAME DAY FREE!" World’s largest warehouse of Factory Sealed GE 90-30 PLC, GENIUS I/O and RX7i PACSystem.highlight_off

PDF Electric & Supply Inc. sells new, new surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with PDF Electric & Supply Inc. and not the manufacturer. PDF Electric & Supply Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners.